Efficacy of color lenses in abolishing photosensitivity: Beyond the one-type-fits-all approach?
Autor: | Ana Checa-Ros, Stefano Seri, Antonella Cerquiglini, D. Kasteleijn-Nolst Trenite, A. Edson-Scott, Bryony Carr |
---|---|
Rok vydání: | 2021 |
Předmět: |
medicine.medical_specialty
business.industry medicine.disease law.invention Lens (optics) Behavioral Neuroscience Epilepsy Neurology Photosensitivity Photosensitive epilepsy Eeg data Tolerability law Ophthalmology medicine sense organs Neurology (clinical) Intermittent photic stimulation business Pattern sensitivity |
Zdroj: | Epilepsybehavior : EB. 124 |
ISSN: | 1525-5069 |
Popis: | Objective Red-light filtering lenses represent an additional option to medication in photosensitive epilepsy. Blue lenses (Clarlet Z1 F133) can dramatically reduce seizure frequency, with a substantial restriction in luminance that can limit their applicability in daily life. We investigated the efficacy of 4 blue lenses with higher transmittance and reduced chromatic distortion in abolishing the photoparoxysmal EEG response (PPR) compared to the gold-standard Z1 lenses. Methods We reviewed EEG data during photic-and pattern stimulation in 19 consecutive patients (6–39 years) with photosensitivity (PS). Stimulation was performed at baseline and while wearing Z1 and the four new lenses. Lenses were tested in the same session by asking the patient to wear them in a sequentially randomized fashion while stimulating again with the most provocative photic/pattern stimuli. The primary outcome was the change in the initial PPR observed for each lens, categorized as no change, reduction, and abolition. Results Photosensitivity was detected in 17 subjects (89.5%); pattern sensitivity (PtS) was identified in 14 patients (73.7%). The highest percentages of PPR abolition/reduction were observed with Z1, for both PS and PtS. Regarding the new lenses, B1 + G1 offered the best rates, followed by B1 + G2. B1 + G3 and B1 showed lower efficacy rates, particularly for PtS. In the comparative analysis, no significant differences in PPR suppression were detected between the five lenses for PS. For PtS, the capacity of Z1 for PPR abolition was significantly higher compared with B1 + G3 and B1. Conclusions This preliminary study suggests efficacy of the new group of blue lenses with potentially greater tolerability, particularly in regions with fewer sunlight hours during winter. In line with the current trend for personalized approach to treatment, this study suggests that in some patients there might be scope in extending the testing to offer the lens with the higher transmittance effective in abolishing the PPR. |
Databáze: | OpenAIRE |
Externí odkaz: |