Allergen immobilisation and signal amplification by quantum dots for use in a biosensor assay of IgE in serum
Autor: | Marcus J. Swann, Francesco Damin, Geoffrey W. Platt, Marina Cretich, Gilbert Skorski, Marcella Chiari, Isabelle Metton |
---|---|
Rok vydání: | 2013 |
Předmět: |
Streptavidin
genetic structures Polymers Biomedical Engineering Biophysics Protozoan Proteins Antigens Protozoan Biosensing Techniques Immunoglobulin E medicine.disease_cause chemistry.chemical_compound Allergen Antigen Quantum Dots Electrochemistry medicine Hypersensitivity Humans biology General Medicine Polymer coating Allergens Molecular biology Antibodies Anti-Idiotypic Interferometry chemistry IgG binding Quantum dot biology.protein Antibody Biosensor Biotechnology |
Zdroj: | Biosensors and Bioelectronics Biosensors & bioelectronics 52 (2014): 82–88. doi:10.1016/j.bios.2013.08.019 info:cnr-pdr/source/autori:Platt G.W.; Damin F.; Swann M.J.; Metton I.; Skorski G.; Cretich M.; Chiari M./titolo:Allergen immobilisation and signal amplification by quantum dots for use in a biosensor assay of IgE in serum/doi:10.1016%2Fj.bios.2013.08.019/rivista:Biosensors & bioelectronics/anno:2014/pagina_da:82/pagina_a:88/intervallo_pagine:82–88/volume:52 |
ISSN: | 1873-4235 |
DOI: | 10.1016/j.bios.2013.08.019 |
Popis: | The production of biosensors for point of care diagnostics usually requires the immobilisation and storage of protein (for example, antigen or antibody) on a sensor surface, in a manner that retains a high degree of activity and low levels of non-specific binding. These characteristics have been assessed for polymer immobilised antigens (allergens) using an IgG binding assay and demonstrated further by assay with serum containing reactive IgEs. The activity of allergens immobilised on sensor chips using copoly(DMA–NAS–MAPS) and a spotting technique, as well as the specificity of their binding interactions with cognate immunoglobulins was assessed using Dual Polarisation Interferometry (DPI). The data obtained indicate that the allergens studied remain stable over long periods of time (at least 114 days). This performance compared favourably with other immobilisation methods. Allergen coated chips were tested in an anti-casein IgE assay using human serum from allergic and non-allergic donors. Detection of both total Ig and specific IgE was demonstrated using a secondary anti-IgE antibody. Furthermore, optical signal enhancement with streptavidin conjugated quantum dots was shown to yield responses for samples below 0.84 ng/mL (0.35 KU/L) of IgE, which overlap with the industrial quasi-standard ImmunoCAP ® and is the clinically relevant threshold used to classify serum samples from allergic individuals. |
Databáze: | OpenAIRE |
Externí odkaz: |