Young's Modulus of Bilateral Infraspinatus Tendon Measured in Different Postures by Shear Wave Elastography Before and After Exercise

Autor: Yi Long, Yiyong Tang, Jingyi Hou, Bing Ou, Yamuhanmode Alike, Congda Zhang, Jiayi Wu, Qingyue Li, Rui Yang, Yuanhao Zhang, Chuanhai Zhou, Menglei Yu, Fangqi Li
Rok vydání: 2021
Předmět:
Zdroj: Orthopaedic Surgery
Orthopaedic Surgery, Vol 13, Iss 5, Pp 1570-1578 (2021)
ISSN: 1757-7861
Popis: Objective To investigate the Young's modulus value of infraspinatus tendons using shear wave elastography (SWE) technique in normal adults, and to analyze the influence of gender, postures, exercise, and dominant side on Young's modulus of infraspinatus tendons. Methods This is a prospective cross‐sectional study. From January 2019 to July 2020, 14 healthy subjects were identified, including seven males and seven females aged between 24 to 34, with a mean age of 27.67 ± 3.08 years. The Young's modulus of their infraspinatus tendons was measured by two operators using SWE in neutral and maximum external rotation positions of both sides before exercise and the dominant side after exercise. The Young's modulus values in different sexes, different postures, before vs after exercise, and dominant vs non‐dominant side were statistically analyzed. Results All 14 subjects completed the data collection process. The mean Young's modulus values of infraspinatus tendon for dominant sides in neutral position were 33.04 ± 3.01 kPa for males and 28.76 ± 3.09 kPa for females. And for non‐dominant sides in the neutral position, the values were 33.02 ± 2.38 kPa for males and 28.86 ± 2.47 kPa for females. In the maximum external rotation position, the values for dominant sides were 50.19 ± 4.86 kPa for males and 42.79 ± 4.44 kPa for females, and for non‐dominant sides were 50.95 ± 3.24 kPa for males and 42.42 ± 3.66 kPa for females. After exercise, the mean Young's modulus values of infraspinatus tendon for dominant sides in neutral position were 54.56 ± 3.76 kPa for males and 46.66 ± 5.99 kPa for females. And for the maximum external rotation position, the values were 59.13 ± 3.78 kPa for males and 54.49 ± 5.67 kPa for females. The Young's modulus of infraspinatus tendon in the neutral and maximum external rotation positions showed statistically significant differences in males and females, as well as before and after exercise (P 0.05). Intergroup reliability between both operators was excellent (ICC > 0.85). Conclusion There are gender‐related differences and post‐exercise increase in Young's modulus, yet such a difference cannot be witnessed between the dominant and non‐dominant sides.
The Young's modulus value of normal adults' infraspinatus tendons can be obtained with SWE. Our study showed no significant difference in hardness of infraspinatus tendons between the dominant side and the non‐dominant side. The hardness increases significantly after exercise, and there is a hardness difference between men and women.
Databáze: OpenAIRE