An Analytical Technique to Elucidate Field Impurities From Manufacturing Uncertainties of an Double Pancake Type HTS Insert for High Field LTS/HTS NMR Magnets
Autor: | Min Cheol Ahn, Yukikazu Iwasa, E.S. Bobrov, Juan Bascunan, Seungyong Hahn |
---|---|
Rok vydání: | 2009 |
Předmět: |
Bitter electromagnet
High-temperature superconductivity Materials science Field (physics) Condensed matter physics Nuclear engineering Analytical technique Superconducting magnet Condensed Matter Physics Article Electronic Optical and Magnetic Materials law.invention law Electromagnetic coil Condensed Matter::Superconductivity Magnet Electrical and Electronic Engineering Order of magnitude |
Zdroj: | IEEE Transactions on Applied Superconductivity. 19:2281-2284 |
ISSN: | 1558-2515 1051-8223 |
DOI: | 10.1109/tasc.2009.2018808 |
Popis: | This paper addresses adverse effects of dimensional uncertainties of an HTS insert assembled with double-pancake coils on spatial field homogeneity. Each DP coil was wound with Bi2223 tapes having dimensional tolerances larger than one order of magnitude of those accepted for LTS wires used in conventional NMR magnets. The paper presents: 1) dimensional variations measured in two LTS/HTS NMR magnets, 350 MHz (LH350) and 700 MHz (LH700), both built and operated at the Francis Bitter Magnet Laboratory; and 2) an analytical technique and its application to elucidate the field impurities measured with the two LTS/HTS magnets. Field impurities computed with the analytical model and those measured with the two LTS/HTS magnets agree quite well, demonstrating that this analytical technique is applicable to design a DP-assembled HTS insert with an improved field homogeneity for a high-field LTS/HTS NMR magnet. |
Databáze: | OpenAIRE |