Application of UV absorbance and electron-donating capacity as surrogates for micropollutant abatement during full-scale ozonation of secondary-treated wastewater
Autor: | Adriano Joss, Nicolas Walpen, Urs von Gunten |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2022 |
Předmět: |
dissolved organic-matter
Environmental Engineering Ozone ozonation uv absorbance bromate formation Residual on-line monitoring removal efficiency Absorbance chemistry.chemical_compound Dissolved organic carbon initial phase Waste Management and Disposal Effluent Water Science and Technology Civil and Structural Engineering correlation models bromide Ecological Modeling transformation electron-donating capacity Bromate Pollution Wastewater chemistry ozone decomposition kinetics Environmental chemistry micropollutant abatement Sewage treatment chemical oxidation Ozonation Micropollutant abatement Electron-donating capacity UV absorbance On-line monitoring |
Zdroj: | Water Research, 209 |
ISSN: | 0043-1354 1879-2448 |
Popis: | Ozonation of secondary-treated wastewater for the abatement of micropollutants requires a reliable control of ozone doses. Changes in the UV absorbance of dissolved organic matter (DOM) during ozonation allow to estimate micropollutant abatement on-line and were therefore identified as feed-back control parameter. In this study, the suitability of the electron-donating capacity (EDC) as an additional surrogate parameter which is independent of optical DOM properties was evaluated during full-scale ozonation. For this purpose, a recently developed EDC analyzer was enhanced to enable continuous on-line EDC and UV absorbance measurements. During a multi-week monitoring campaign at the wastewater treatment plant of Zurich, Switzerland, specific ozone doses were varied from 0.13 to 0.91 mgO3⋅mgDOC−1 and selected micropollutants with different ozone reactivities were analyzed by LC-MS in conjunction with bromate analysis by IC-MS. In agreement with previous laboratory studies, the relative residual UV absorbance and EDC both decreased exponentially as a function of the specific ozone dose and, in comparison to the residual UV absorbance, residual EDC values showed a more pronounced decrease at low specific ozone doses ≤0.34 mgO3⋅mgDOC−1. Logistic regression models allowed to estimate relative residual micropollutant concentrations in the ozonation effluent using either the residual UV absorbance or EDC as explanatory variable. Averaging those models along the explanatory variables allowed to estimate target values in relative residual UV absorbances and EDC for specific micropollutant abatement targets. In addition, both parameters allowed to identify conditions with elevated conversions of bromide to bromate. Taken together, these findings show that the integration of relative residual EDC values as a second control parameter can improve existing absorbance-based ozonation control systems to meet micropollutant abatement targets, particularly for treatment systems where low ozone doses are applied. Water Research, 209 ISSN:0043-1354 ISSN:1879-2448 |
Databáze: | OpenAIRE |
Externí odkaz: |