Time Factors Hook Operative Time Bone Nails 03 medical and health sciences 0302 clinical medicine medicine Fluoroscopy Humans Orthopedics and Sports Medicine 030212 general & internal medicine Simulation Training Femoral neck 030222 orthopedics medicine.diagnostic_test business.industry Virtual Reality Surgical training Surgery Femoral Neck Fractures medicine.anatomical_structure Lesser Trochanter Traumatology Hook plate Pin distance Implant Clinical Competence business Bone Plates |
Zdroj: | European journal of orthopaedic surgerytraumatology : orthopedie traumatologie. 29(7) |
ISSN: | 1432-1068 |
Popis: | A virtual reality simulator developed for orthopaedic and trauma surgical training has been introduced. However, it is unclear whether the experiences of actual surgery are reflected in virtual reality simulation surgery (VRSS) using a simulator. The aim of this study is to investigate whether the results in VRSS differ between a trauma expert and a trauma novice. In Group A (expert), there are ten orthopaedic trauma surgeons and in Group B (novice) ten residents within 2 years after medical school graduation. VRSS for a femoral neck fracture using Hansson hook-pins (Test 1) and Hansson twin hook plate (Test 2) was performed. The parameters evaluated were total procedure time (s), fluoroscopy time (s), number of times X-ray was used (defined by the number of times the foot pedal was used), number of retries in guide placement, and final implant position. In Test 1, the averages of four parameters (distance to posterior cortex (p = 0.009), distal pin distance above lesser trochanter (p = 0.015), distal pin hook angular error (p = 0.004), and distal pin tip distance to centre (lateral) (p = 0.015)) were significantly different between Groups A and B. In Test 2, no parameters in a mean were significantly different between groups, but seven parameters in a variance (guide wire distance to joint surface (p = 0.0191), twin hook length outside barrel (p = 0.011), twin hook tip distance to centre (lateral) (p = 0.042), twin hook distance to centre of lateral cortex (lateral) (p = 0.016), plate end alignment error (lateral) (p = 0.027), guide wire angle with lateral cortex (front) (p = 0.024), and 3.2-mm drill outside cortex (p = 0.000)) were significantly different between groups. In Test 1, Group B showed significantly longer fluoroscopy time than Group A (p = 0.044). In Test 2, Group B showed significantly fewer instances of X-ray use than Group A (p = 0.046). Our study showed that the experiences of actual surgery are reflected in the result of VRSS using the simulator. |
Databáze: | OpenAIRE |
Externí odkaz: |