Estimation of ocular axial length with optometric parameters is not accurate
Autor: | Alejandro Tello, Juan José Rey, Angélica M. Prada, Sergio Eduardo Serrano Gómez, Virgilio Galvis |
---|---|
Rok vydání: | 2022 |
Předmět: |
medicine.medical_specialty
Adolescent Open angle glaucoma Population Spherical equivalent Refraction Ocular law.invention Cornea 03 medical and health sciences 0302 clinical medicine law Ophthalmology Myopia medicine Humans Child education Mathematics education.field_of_study Keratometer Vision Tests Retinal detachment General Medicine medicine.disease Axial Length Eye Concordance correlation coefficient Ocular axial length 030221 ophthalmology & optometry Maculopathy Glaucoma Open-Angle 030217 neurology & neurosurgery Optometry |
Zdroj: | Contact Lens and Anterior Eye. 45:101448 |
ISSN: | 1367-0484 |
Popis: | Myopia is a worldwide major public concern, aside from the visual disturbance needing optical correction, myopia may be associated with open angle glaucoma, retinal detachment and myopic maculopathy. The higher the myopia the higher the risk for retinal associated comorbidities, and the axial length is the more important measure to estimate risk of visual impairment. Recently a formula to predict axial length using spherical equivalent and keratometry was proposed, with the intention of categorizing the risk of visual impairment with Tideman et al. classification. Purpose To evaluate the accuracy of an axial length prediction formula in a Colombian population 8–17 years old. Methods Children from MIOPUR study with optical biometer axial length measure (AL), manifest refraction and keratometry were included in the analysis. Predicted axial length (PAL) was calculated with the prediction formula. A Bland-Altman assessment was conducted, and the concordance correlation coefficient was measured. Proposed classification of AL to establish risk of visual loss was used with measured AL and with PAL. The percentage of eyes misclassified was then established. Results A total of 2129 eyes were included in the analysis. Mean difference of axial length (actual AL minus PAL) was −0.516 mm (−1.559 mm – 0.528 mm). Concordance correlation coefficient (CCC) of 0.656 (IC95 0.636-0.675) was found between the real AL and PAL. PAL differed from measured AL by 1 mm or more in 16.58 %, and by 2 mm or more, in 0.61 % of the eyes. In myopic eyes, PAL was in average 0.426 mm longer than the AL actually measured with CCC of 0.714 (IC95 0.666−0.761). PAL differed from measured AL by 1 mm or more in 21.92 %, and by 2 mm or more, in 0.45 % of the myopic eyes. The study revealed that 15.03 % of all eyes, and 29.81 % of myopic eyes, were misclassified when PAL was used. Conclusions The proposed axial length prediction formula was not accurate, and it did not adequately classify risk of visual impairment in myopic eyes in a group of Colombian children. We consider that it is not possible to predict the axial length based only on optometric data, such as the corneal radius of curvature and the spherical equivalent. This is very possibly related to the variability of crystalline lens power within a population. |
Databáze: | OpenAIRE |
Externí odkaz: |