Metal artifact reduction MRI for total ankle replacement sagittal balance evaluation
Autor: | Lew C. Schon, Apisan Chinanuvathana, Steven Stern, Lucas Furtado da Fonseca, Cesar de Cesar Netto, Jan Fritz |
---|---|
Rok vydání: | 2019 |
Předmět: |
Adult
Male Intraclass correlation Concordance medicine.medical_treatment Radiography Ankle replacement Periprosthetic Arthroplasty Replacement Ankle Prosthesis Fitting Humans Medicine Orthopedics and Sports Medicine Prospective Studies Tibia Reduction (orthopedic surgery) Aged business.industry Middle Aged Magnetic Resonance Imaging Sagittal plane medicine.anatomical_structure Female Anatomic Landmarks Artifacts business Nuclear medicine Ankle Joint |
Zdroj: | Foot and Ankle Surgery. 25:739-747 |
ISSN: | 1268-7731 |
DOI: | 10.1016/j.fas.2018.09.005 |
Popis: | Background Restoration of anatomical relationship between talus and tibia is crucial for longevity of total ankle replacement (TAR). Weight-bearing (WB) radiographs are the standard for evaluating the sagittal balance alignment, but are prone to rotational misalignment and altered measurements. Metal artifact reduction sequence (MARS) MRI allows visualization of periprosthetic landmarks and alignment of the image plane to the true sagittal axis of the implant. The purpose of this study was to compare TAR sagittal balance measurements on MARS MRI and WB radiographs. Methods Twenty-three subjects with TAR [10 men/13 women, age 60 (41–73) years; 13 (3–24) months post-op] underwent MARS MRI and standard lateral WB radiographs. Standardized MARS MR images were aligned to the sagittal talar component axis. Three observers performed sagittal balance alignment measurements twice in an independent, random and blinded fashion. Lateral Talar Station (LTS), tibial axis-to-talus (T-T) ratio and normalized tibial axis-to-lateral-process (T-L) distance were measured. Concordance correlation coefficients (CCC) and intraclass correlation coefficients (ICC) were used for statistical analysis. In addition, mixed effects linear models were employed to assess overall concordance of the two image types. Results The intraobserver agreement was excellent for radiographic (CCC = 0.96) and MRI (CCC = 0.90–0.97) measurements. Interobserver agreements were good-to-excellent with overall slightly higher agreements for MRI (ICC = 0.78–0.94) than radiography (ICC = 0.78–0.90) measurements. The T-T ratios of radiographs and MRI showed a high degree of concordance, whereas LTS was significantly lower on MRI when compared with radiographs, and T-L distance showed notable disagreement between the two imaging types. Conclusion Sagittal balance measurements performed on standardized weight-bearing radiographs and standardized MARS MRI demonstrate substantial correlation and similarity. Given its high intra and interobserver agreement, MARS MRI may be helpful for the evaluation of TAR sagittal balance. Level of evidence: Level II - Prospective Comparative Study. |
Databáze: | OpenAIRE |
Externí odkaz: |