An effective method to avoid charge leakage along the surface in voltage response measurement
Autor: | Han Yongsen, Changyou Suo, Zhonghua Li, Yunlong Sun |
---|---|
Rok vydání: | 2021 |
Předmět: |
010302 applied physics
Materials science business.industry fungi food and beverages Charge (physics) Dielectric 01 natural sciences 010305 fluids & plasmas Volume (thermodynamics) 0103 physical sciences Electrode Optoelectronics Effective method business Polarization (electrochemistry) Instrumentation Voltage Leakage (electronics) |
Zdroj: | The Review of scientific instruments. 92(5) |
ISSN: | 1089-7623 |
Popis: | The voltage response measurement is a non-destructive method to diagnose the aging condition of insulation and is used extensively. The characteristics about the volume polarization and resistance can be obtained by analyzing the measured decay or return voltage of a charged dielectric, which is important for aging diagnosis. To eliminate the influence of the charges leaking along the sample surface on the voltage response analysis, we present an effective three electrode configuration with a potential guard electrode. The voltage decay results show that adopting electrodes with a potential guard electrode can effectively avoid charge leakage along the sample surface. |