The recoil proton dose at a bone-tissue interface irradiated by fast neutrons
Autor: | R C Lawson |
---|---|
Rok vydání: | 1967 |
Předmět: |
animal structures
Materials science Quantitative Biology::Tissues and Organs Nuclear Theory Physics::Medical Physics Bone tissue Models Biological Bone and Bones Imaging phantom Spectral line Quantitative Biology::Cell Behavior Recoil proton medicine Radiology Nuclear Medicine and imaging Neutron Irradiation Radiometry Nuclear Experiment Neutrons Radiological and Ultrasound Technology business.industry Radiochemistry technology industry and agriculture Neutron temperature medicine.anatomical_structure Mockup Polyethylenes Protons Nuclear medicine business |
Zdroj: | Physics in Medicine and Biology. 12:551-554 |
ISSN: | 0031-9155 |
DOI: | 10.1088/0031-9155/12/4/008 |
Popis: | The recoil proton dose in a body irradiated by fast neutrons is normally determined using a polythene phantom filled with a liquid simulating soft tissue. The perturbation to the dose by the presence of bone is considered for two parallel slabs of bone surrounded by tissue. Typical dose curves in bone and tissue of various thicknesses are illustrated for 14 Mev neutrons, and can readily be applied to neutrons of lower energyurbation on the recoil proton LET spectra is discussed. |