Application of multi-directional forged titanium for prosthetic crown fabrication by CAD/CAM

Autor: Chikahiro Ohkubo, Hiromi Miura, Norishige Kawanishi, Masateru Anzai, Kazuhide Seimiya, Katsuhiko Kimoto, Tomonari Kumasaka, Erika Inoue, Noriyuki Hoshi, Tohru Hayakawa
Rok vydání: 2021
Předmět:
Zdroj: Dental Materials Journal. 40:1049-1054
ISSN: 1881-1361
0287-4547
DOI: 10.4012/dmj.2020-351
Popis: Titanium are often used as dental materials, pure titanium present low strength and titanium alloy is reported poor biocompatibility, respectively. To overcome the problem, we fabricated high-strength multi-directional forged (MDF) titanium with improved mechanical properties without changing the chemical composition and evaluated its applicability in prosthetic crowns. Cutting tests: the average absolute value of the difference before and after cutting was calculated as the uncut amount. Surface evaluations: MDF titanium, pure titanium, and the Ti-6Al-4V alloy were the surface properties (the surface roughness, the contact angles, glossiness) of the samples were evaluated. The fitness test used digital data. These demonstrated that the good workability of high-strength MDF titanium. The surface-roughness and contact-angle properties of MDF titanium and pure titanium were similar. The fitness test showed no significant differences between MDF titanium and pure titanium crowns. These results suggest that MDF titanium is promising for fabricating prosthetic crowns in dental applications.
Databáze: OpenAIRE