Measuring HRQoL following heart valve surgery: the HeartQoL questionnaire is a valid and reliable core heart disease instrument

Autor: Selina Kikkenborg Berg, Lau Caspar Thygesen, Kirstine Lærum Sibilitz, Marie Skov Kristensen, Susanne S. Pedersen, Neil Oldridge, Charlotte N Grønset, Graziella Zangger, Ann-Dorthe Zwisler
Rok vydání: 2019
Předmět:
Zdroj: Grønset, C N, Thygesen, L C, Berg, S K, Zangger, G, Kristensen, M S, Sibilitz, K L, Pedersen, S S, Oldridge, N B & Zwisler, A-D 2019, ' Measuring HRQoL following heart valve surgery : the HeartQoL questionnaire is a valid and reliable core heart disease instrument ', Quality of Life Research, vol. 28, no. 5, pp. 1245-1253 . https://doi.org/10.1007/s11136-018-02098-1
ISSN: 1573-2649
0962-9343
DOI: 10.1007/s11136-018-02098-1
Popis: PURPOSE: Patient-reported health-related quality of life is a complementary healthcare outcome and important when assessing treatment efficacy. Using COSMIN methodological recommendations, this study evaluates the validity and reliability of a core heart disease-specific health-related quality of life questionnaire, the HeartQoL questionnaire (Danish version) in a sample of patients following heart valve surgery.DESIGN: This project involved a cross-sectional validity study and a test-retest reliability study.METHODS: Eligible patients completed the HeartQoL, the SF-36 health survey questionnaire, and the Hospital Anxiety and Depression Scale following heart valve surgery. Construct validity was tested using a priori hypotheses. Internal consistency reliability was assessed with Cronbach's alpha. An independent sample of patients participated in the test-retest study and reproducibility was determined with relative [intra-class correlation coefficient (ICC)] and absolute reliability [standard error of measurement (SEM) and smallest detectable change (SDC)].RESULTS: Internal consistency was high with Cronbach's alpha ≥ 0.87. ICC was 0.86-0.92. SEM ranged from 0.17 to 0.26 points and SDC ranged from 0.5 to 0.7 points. Construct validity was confirmed with 87% of all a priori hypotheses for predicted variables.CONCLUSIONS: The HeartQoL questionnaire demonstrates acceptable construct validity, internal consistency, and test-retest reproducibility in patients following heart valve surgery. Future studies should focus on assessing the responsiveness of the HeartQoL questionnaire over time and following heart valve surgery.
Databáze: OpenAIRE
Nepřihlášeným uživatelům se plný text nezobrazuje