Feasibility of a 2nd generation MR-compatible manipulator for transrectal prostate biopsy guidance
Autor: | Dennis Bosboom, Joyce G. R. Bomers, Jurgen J. Fütterer, J. Sabisch, G. H. Tigelaar, Derya Yakar |
---|---|
Přispěvatelé: | Basic and Translational Research and Imaging Methodology Development in Groningen (BRIDGE) |
Rok vydání: | 2017 |
Předmět: |
GUIDED BIOPSY
medicine.medical_specialty ULTRASOUND FUSION Biopsy Mr compatible 030232 urology & nephrology Cancer detection 030218 nuclear medicine & medical imaging 03 medical and health sciences Prostate cancer 0302 clinical medicine Prostate medicine Radiology Nuclear Medicine and imaging COHORT Manipulator Transrectal Prostate Biopsy medicine.diagnostic_test business.industry CANCER DETECTION Feasibility General Medicine Robotics medicine.disease medicine.anatomical_structure Radiology Nuclear Medicine and imaging Urological cancers Radboud Institute for Health Sciences [Radboudumc 15] Radiology business Image-Guided Biopsy Rare cancers Radboud Institute for Health Sciences [Radboudumc 9] MRI |
Zdroj: | European Radiology, 27, 1776-1782 European Radiology, 27(4), 1776-1782. SPRINGER European Radiology, 27, 4, pp. 1776-1782 |
ISSN: | 0938-7994 |
Popis: | Contains fulltext : 173101.pdf (Publisher’s version ) (Open Access) OBJECTIVES: To assess the feasibility of a 2nd generation MR-compatible, remote-controlled manipulator (RCM) as an aid to perform MR-guided transrectal prostate biopsy in males with suspicion of prostate cancer (PCa). METHODS: This prospective phase I study was approved by the local ethical committee and written informed consent was obtained from each patient. Twenty patients with >/=1 cancer suspicious region (CSR) with a PI-RADS score of >/=3 detected on the diagnostic multi-parametric MRI and no prior prostate treatment underwent MR-guided biopsy with the aid of the RCM. Complications were classified according to the modified Clavien system for reporting surgical complications. For evaluation of the workflow, procedure- and manipulation times were recorded. RESULTS: All CSR's (n=20) were reachable with the MR-compatible RCM and the cancer detection rate was 70 %. The median procedure time was 36:44 minutes (range, 23 - 61 minutes) and the median manipulation time for needle guide movement was 5:48 minutes (range, 1:15 - 18:35 minutes). Two Clavien grade 1 complications were reported. CONCLUSIONS: It is feasible and safe to perform transrectal MR-guided prostate biopsy using a MR-compatible RCM as an aid. It is a fast and efficient way to biopsy suspicious prostate lesions with a minimum number of biopsies per patient. KEY POINTS: * It is feasible to perform transrectal prostate biopsy using a MR-compatible RCM. * Using a RCM for MR-guided biopsy is safe, fast, and efficient. * All cancer suspicious regions were reachable with the RCM. |
Databáze: | OpenAIRE |
Externí odkaz: |