Clinical implementation of respiratory‐gated spot‐scanning proton therapy: An efficiency analysis of active motion management
Autor: | Jon J. Kruse, Michael G. Herman, Erik J. Tryggestad, Edgar Gelover, Amanda J. Deisher, Jedediah E. Johnson |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
medicine.medical_specialty
Respiratory-Gated Imaging Techniques Computer science Movement Continuous delivery Imaging phantom 030218 nuclear medicine & medical imaging Breath Holding 03 medical and health sciences Active motion DICOM 0302 clinical medicine motion management medicine Proton Therapy Radiation Oncology Physics Humans Radiology Nuclear Medicine and imaging Medical physics Radiation treatment planning Instrumentation Proton therapy Retrospective Studies Radiation Data collection business.industry Phantoms Imaging Radiotherapy Planning Computer-Assisted Radiotherapy Dosage Thoracic Neoplasms Prognosis spot‐scanning 030220 oncology & carcinogenesis Abdominal Neoplasms breath‐holding Radiotherapy Intensity-Modulated business Quality assurance phase‐gating Synchrotrons |
Zdroj: | Journal of Applied Clinical Medical Physics |
ISSN: | 1526-9914 |
Popis: | Purpose The aim of this work is to describe the clinical implementation of respiratory‐gated spot‐scanning proton therapy (SSPT) for the treatment of thoracic and abdominal moving targets. The experience of our institution is summarized, from initial acceptance and commissioning tests to the development of standard clinical operating procedures for simulation, motion assessment, motion mitigation, treatment planning, and gated SSPT treatment delivery. Materials and methods A custom respiratory gating interface incorporating the Real‐Time Position Management System (RPM, Varian Medical Systems, Inc., Palo Alto, CA, USA) was developed in‐house for our synchrotron‐based delivery system. To assess gating performance, a motion phantom and radiochromic films were used to compare gated vs nongated delivery. Site‐specific treatment planning protocols and conservative motion cutoffs were developed, allowing for free‐breathing (FB), breath‐holding (BH), or phase‐gating (Ph‐G). Room usage efficiency of BH and Ph‐G treatments was retrospectively evaluated using beam delivery data retrieved from our record and verify system and DICOM files from patient‐specific quality assurance (QA) procedures. Results More than 70 patients were treated using active motion management between the launch of our motion mitigation program in October 2015 and the end date of data collection of this study in January 2018. During acceptance procedures, we found that overall system latency is clinically‐suitable for Ph‐G. Regarding room usage efficiency, the average number of energy layers delivered per minute was |
Databáze: | OpenAIRE |
Externí odkaz: |