Evaluation of implant esthetics using eight objective indices-Comparative analysis of reliability and validity
Autor: | Bernhard Pommer, Markus Hof, Rudolf Seemann, Nabeel Umar, Werner Zechner, Nikolaus Budas |
---|---|
Rok vydání: | 2018 |
Předmět: |
050109 social psychology
Esthetics Dental 03 medical and health sciences 0302 clinical medicine Consistency (statistics) Statistical significance Premolar medicine Humans 0501 psychology and cognitive sciences Reliability (statistics) Dental Implants Observer Variation Orthodontics Reproducibility business.industry 05 social sciences Reproducibility of Results Contrast (statistics) 030206 dentistry medicine.anatomical_structure Patient Satisfaction Implant Objective evaluation Oral Surgery business |
Zdroj: | Clinical Oral Implants Research. 29:697-706 |
ISSN: | 0905-7161 |
DOI: | 10.1111/clr.13261 |
Popis: | Objectives The aim of the present study was to give a detailed analysis on eight proposed implant esthetic indices including a total of 48 parameters with respect to validity and reproducibility as well as its correlation to patients' perception of esthetics. Material and methods Standardized intraoral photographs of 189 patients with 189 implant-supported crowns and adjacent peri-implant soft tissue in the esthetic zone (central and lateral incisors, canine, first premolar) served as basis for this evaluation. Eight indices (Papilla Index [PI], Pink Esthetic Score [PES], Implant Crown Aesthetic Index [ICAI], Pink and White Esthetic Score [PES/WES], Complex Esthetic Index [CEI], Implant Aesthetic Score [IAS], Subjective Esthetic Score [SES], and Rompen Index) with a total of 48 parameters were selected. Esthetic evaluation was performed twice by five examiners with an interval of 4 weeks between the evaluations. Results A total of 1,890 evaluations including eight esthetic indices served as basis for the statistical analysis. Among the overall main scores tested for inter-rater reliability, the highest ρ ^ inter values were computed for CEI, PES, PI, and IAS scores. By contrast, SES and Rompen showed the worst inter-rater reliability, respectively. The highest level of intra-rater reproducibility was noted for PI, PES, and CEI. The lowest level of intra-rater reproducibility showed Rompen, SES, and ICA. The Papilla Index demonstrated the highest level of inter-rater reliability. The remainder of the single variables (n = 46) did not reach the ρ ^ inter level of 0.6. The single variables PI mesial, PI distal as well as CEI P4 showed the highest ρ ^ intra with statistical significance higher than 0.8. The lowest agreement was observed among the variables ICA3, WES5, and IASm2. In general, VAS did not show any good correlation to the esthetic indices proposed so far. The influence of esthetic parameters on subjective patient satisfaction was generally low. Conclusion In conclusion, significant differences regarding reliability and validity could be observed in the present comparison of eight esthetic indices. Objective evaluation of the esthetic outcome of implant therapy inherently fails to reflect subjective patient opinion, however, requires consistency of results to enable between-study comparison and meta-analysis. |
Databáze: | OpenAIRE |
Externí odkaz: |