High throughput screening of ultrafiltration and diafiltration processing of monoclonal antibodies via the ambr® crossflow system
Autor: | Michael K. Wismer, Lara Fernandez-Cerezo, Jennifer M. Pollard, InKwan Han |
---|---|
Rok vydání: | 2020 |
Předmět: |
0106 biological sciences
High concentration Materials science business.industry High-throughput screening 010401 analytical chemistry Antibodies Monoclonal 01 natural sciences Fractionation Field Flow Transmembrane pressure High-Throughput Screening Assays 0104 chemical sciences Cross-flow filtration Diafiltration Cartridge Biopharmaceutical industry 010608 biotechnology Pressure Bioprocess Process engineering business Filtration Biotechnology |
Zdroj: | Biotechnology Progress. 36 |
ISSN: | 1520-6033 8756-7938 |
Popis: | As the biopharmaceutical industry moves toward high concentration of monoclonal antibody drug substance, additional development is required early on when material is still limited. A key constraint is the availability of predictive high-throughput low-volume filtration screening systems for bioprocess development. This particularly impacts final stages such as ultrafiltration/diafiltration steps where traditional scale-down systems need hundreds of milliliters of material per run. Recently, the ambr® crossflow system has been commercialized by Sartorius Stedim Biotech (SSB) to meet this need. It enables parallel high throughput experimentation by only using a fraction of typical material requirements. Critical parameters for predictive filtration systems include loading, mean transmembrane pressure (Δ P ¯ TMP ), and crossflow rate (QF ). While axial pressure drop (ΔPaxial ) across the cartridge is a function of these parameters, it plays a key role and similar values should result across scales. The ambr® crossflow system is first presented describing typical screening experiments. Its performance is then compared to a traditional pilot-scale tangential flow filtration (TFF) at defined conditions. The original ambr® crossflow (CF) cartridge underperformed resulting in ~20x lower ΔPaxial than the pilot-scale TFF flat-sheet cassette. With an objective to improve the scalability of the system, efforts were made to understand this scale difference. The ambr® CF cartridge was successfully modified by restricting the flow of the feed channel, and thus increasing its ΔPaxial . Additional studies across a range of loading (100-823 gm-2 ); Δ P ¯ TMP (12-18 psi); and QF (4-8 L/min/m2 ) were conducted in both scales. Comparable flux and aggregate levels were achieved. |
Databáze: | OpenAIRE |
Externí odkaz: |