Trabeculectomy with Ologen implant versus perfluoropropane gas bubble for open angle glaucoma in pseudophakic eyes

Autor: Hossam Youssef Abouelkheir, Tharwat H Mokbel, Ahmed S Elwehidy, Faried M Wagdy, Waleed Abou Samra, Amr Mohammed Elsayed Abdelkader
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: International Journal of Ophthalmology, Vol 14, Iss 4, Pp 510-516 (2021)
Int J Ophthalmol
ISSN: 2227-4898
2222-3959
Popis: AIM: To evaluate the safety and efficacy of augmented trabeculotomy with Ologen versus perfluoropropane in management of pseudophakic glaucoma. METHODS: This is a comparative randomized study included 57 pseudophakic eyes of 57 patients with medically uncontrolled open angle glaucoma (OAG). Twenty-nine patients were allocated in group I (trabeculectomy with Ologen; trab-ologen group), while 28 patients were assigned in group II (trabeculectomy with perfluoropropane gas bubble; trab-C3F8 gas bubble group). RESULTS: The intraocular pressure (IOP) was significantly reduced in both study groups at all postoperative follow up intervals (1wk, 3, 6, 12, 18, 24, 30 and 36mo, P