The pneumatic tube system does not affect complete blood count results; a validation study at a tertiary care hospital
Autor: | Shahina Daar, R. M. Al-Hadhrami, Murtadha Al-Khabori, Khalil Al-Farsi, H. M. Davis, I. S. Al-Azwani, S. Alkindi, Arwa Z. Al-Riyami |
---|---|
Rok vydání: | 2013 |
Předmět: |
Validation study
medicine.medical_specialty Coefficient of determination Oman Correlation coefficient Point-of-Care Systems Clinical Biochemistry Transportation White blood cell medicine Humans Blood Specimen Collection medicine.diagnostic_test Tertiary Healthcare business.industry beta-Thalassemia Biochemistry (medical) Complete blood count Hematology General Medicine Tertiary care hospital Pneumatic tube Confidence interval Blood Cell Count Surgery medicine.anatomical_structure Case-Control Studies business Nuclear medicine |
Zdroj: | International Journal of Laboratory Hematology. 36:514-520 |
ISSN: | 1751-5521 |
DOI: | 10.1111/ijlh.12180 |
Popis: | SummaryIntroduction Effect of the pneumatic tube system (PTS) on sample quality is controversial. Herein we aim at evaluating the impact of sample transportation via the PTS on complete blood count (CBC) results. Methods Duplicate CBC samples from normal donors and anemic patients were sent in parallel to the laboratory for testing through the PTS and the courier (CO). We used scatter plots, Bland–Altman plots, correlation coefficient (r), and coefficient of determination for the validation. Results A total of 115 samples (donors: 59, patients: 56) were tested. There was excellent correlation between both methods for red blood cell parameters (r range = 0.9213–0.9958) and platelet count. White blood cell (WBC) count and differential count showed similar results (r range = 0.8605–0.9821) for all, with exception of basophils which showed modest correlation (r = 0.4827 for patients and 0.5758 for normal donors). Most of the differences in measurement of all CBC parameters were within the 95% confidence interval of the mean difference on Bland–Altman plots. Conclusion Modern PTS can be safely used for transporting CBC samples. |
Databáze: | OpenAIRE |
Externí odkaz: |