Mini-fragment plating of olecranon fractures is comparable to precontoured small-fragment plating

Autor: Harsh Wadhwa, Yousi A. Oquendo, L. Henry Goodnough, Malcolm R. DeBaun, Julius A. Bishop, Michael J. Gardner
Rok vydání: 2021
Předmět:
Zdroj: J Orthop
ISSN: 0972-978X
Popis: INTRODUCTION: Though long-term functional outcomes of olecranon fracture plate fixation are favorable, postoperative implant irritation commonly leads to elective removal. We hypothesized that mini-fragment plates will decrease implant removal compared to precontoured plates. METHODS: Patients with isolated olecranon fracture (AO/OTA 2U1–B1) treated with plate fixation were retrospectively reviewed. Patients were stratified into groups based on whether they underwent open reduction and internal fixation with a (1) surgeon contoured mini-fragment or (2) precontoured olecranon-specific plate. Rates of symptomatic implants and implant removal were compared. RESULTS: 98 and 32 patients were treated with precontoured and mini-fragment plates, respectively. Baseline demographics and comorbidities were similar. Mean follow-up was 20.6 months. There were no differences in rates of postoperative complication (22/98, 22.4% vs. 5/32, 15.6%; p = 0.41) or reoperation (37/98, 37.8% vs. 8/32, 25%; p = 0.19). Symptomatic implants were common in the precontoured cohort (44/98, 44.9% vs. 7/32, 21.9%; p
Databáze: OpenAIRE