Usability of volumetric infusion pumps in pediatric intensive care
Autor: | Elizandra Cassia da Silva Oliveira, Roberto Carlos Lyra da Silva, Gustavo Aires de Arruda, Regina Célia de Oliveira |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.medical_specialty
Technology Assessment Biomedical Qualidade da Assistência à Saúde Critical Care Unidades de Cuidado Intensivo Pediátrico RT1-120 Context (language use) Binomial test Nursing Evaluación de la Tecnología Biomédica Intensive Care Units Pediatric Bombas de Infusion Enfermería Pediátrica 03 medical and health sciences 0302 clinical medicine Intensive care Avaliação da Tecnologia Biomédica medicine Infusion pump Humans Medical physics 030212 general & internal medicine Ergonomía Child General Nursing Infusion Pumps Ergonomia Quality of Health Care Pediatric intensive care unit 030505 public health business.industry Usability Enfermagem Pediátrica Pediatric Nursing Test (assessment) Calidad de la Atención de Salud Unidades de Terapia Intensiva Pediátrica Cross-Sectional Studies Bombas de Infusão Ergonomics Pediatric nursing 0305 other medical science business |
Zdroj: | Revista da Escola de Enfermagem da USP v.55 2021 Revista da Escola de Enfermagem da USP Universidade de São Paulo (USP) instacron:USP Revista da Escola de Enfermagem da USP, Volume: 55, Article number: e03712, Published: 10 MAY 2021 Revista da Escola de Enfermagem da USP, Vol 55 (2021) |
ISSN: | 1980-220X |
Popis: | Objective: To analyze the usability of two infusion pump models in a Pediatric Intensive Care Unit. Method: This is a cross-sectional study of exploratory descriptive quantitative approach. A task was carried out in a controlled environment using infusion pump with 72 nursing staff members from August to September 2018. The Methodological Guideline for Medical Care Equipment Assessment Studies and the quality model proposed by NBR ISO/IEC 9126-1 were followed. Descriptive statistical analysis was used applying Fisher’s exact test, binomial test and Mann-Whitney test. Results: 91.7% of tasks were completed. The infusion pump-2 model was associated (p < 0.001) with operationalization, tasks accomplished with non-conformities, use of a manual calculator (measure effectiveness) and task accomplishment time (measure efficiency). Conclusion: Efficacy and efficiency measures can evidence a better context of usability of IPs and identify interaction failures with the nursing staff to be improved in care practice. RESUMEN Objetivo: Analizar la usabilidad de dos modelos de bombas de infusión en una Unidad de Cuidados Intensivos Pediátricos. Método: Estudio transversal con abordaje descriptivo exploratorio cuantitativo. Se realizó una tarea en ambiente controlado utilizando la bomba de infusión con 72 integrantes del equipo de enfermería de agosto a septiembre de 2018. Como base, se siguió la guía metodológica para los estudios de evaluación de Equipos de Asistencia Médica y el modelo de calidad en uso propuesto por NBR ISO/IEC 9126-1 Se utilizó análisis estadístico descriptivo, aplicando Test Exacto de Fisher, Test Binomial y Test de Mann-Whitney. Resultados: Hubo 91,7% de tareas completadas. El modelo de bomba de infusión-2 se asoció (p |
Databáze: | OpenAIRE |
Externí odkaz: |