Popis: Background Flow cytometric immunophenotyping (FCI) is recognized as a rapid, sensitive, and accurate method for diagnosis of B-cell lymphomas. We observed that FCI failed to identify the clonal B-cell population in several cases of large B-cell lymphoma (DLBCL) when tissue samples were prepared by a commercially available mechanical tissue disaggregation method. We tested a manual tissue disaggregation method and compared it with the mechanical method. Methods FCI findings from 51 cases of DLBCL processed with the mechanical tissue disaggregation method, 27 cases processed using the manual method, and 15 cases processed using a combination of both methods were compared. The histological and immunohistochemical findings in each case were reviewed. Results FCI detected a clonal B-cell population in 88.9% of cases processed by the manual tissue disaggregation method, 66.7% of cases processed by a combination of the manual and mechanical disaggregation methods, and in 62.7% of cases processed solely by the mechanical tissue disaggregation method (P