Bleed-Induced Distortion in Axial Compressors

Autor: T. Walker, Graham Pullan, S. D. Grimshaw
Přispěvatelé: Apollo - University of Cambridge Repository
Rok vydání: 2015
Předmět:
Zdroj: Journal of Turbomachinery. 137
ISSN: 1528-8900
0889-504X
DOI: 10.1115/1.4030809
Popis: In this paper, the influence of non-uniform bleed extraction on the stability of an axial flow compressor is quantified. Non-uniformity can be caused by several geometric factors (for example, plenum chamber size or number of off-take ducts) and a range of configurations is examined experimentally in a single stage compressor. It is shown that non-uniform bleed leads to a circumferential distribution of flow coefficient and swirl angle at inlet to the downstream stage. The resultant distribution of rotor incidence causes stall to occur at a higher flow coefficient than if the same total bleed rate had been extracted uniformly around the circumference. The loss of operating range caused by the non-uniform inlet flow correlates with the peak sector-averaged bleed non-uniformity for all the bleed configurations tested. A connection is made between the analysis of non-uniform bleed extraction and the familiar “DCθ” criterion used to characterize inlet total pressure distortion.Copyright © 2014 by ASME