Generation and Characterization of Test Atmospheres with Nanomaterials
Autor: | B. Sens, E. Leibold, Robert Landsiedel, A.O. Gamer, Lan Ma-Hock, M. Linsenbuehler, B. van Ravenzwaay, T. Frechen |
---|---|
Rok vydání: | 2007 |
Předmět: |
Aerosols
Inhalation Exposure Materials science Atmosphere Health Toxicology and Mutagenesis Inorganic chemistry Oxide Carbon black Toxicology Nanostructures Nanomaterials chemistry.chemical_compound chemistry Chemical engineering Specific surface area Titanium dioxide Zeta potential Animals Particle Particle size Particle Size Environmental Monitoring |
Zdroj: | Inhalation Toxicology. 19:833-848 |
ISSN: | 1091-7691 0895-8378 |
DOI: | 10.1080/08958370701479190 |
Popis: | To ensure the product safety of nanomaterials, BASF has initiated an extensive program to study the potential inhalation toxicity of nanosize particles. As preparation work for upcoming inhalation studies, the following manufactured nanomaterials have been evaluated for their behavior in an exposure system designed for inhalation toxicity studies: titanium dioxide, carbon black, Aerosil R104, Aerosil R106, aluminum oxide, copper(II) oxide, amorphous silicon dioxide, zinc oxide, and zirconium(IV) oxide. As the physicochemical properties and the complex nature of ultrafine aerosols may substantially influence the toxic potential, the particle size, specific surface area, zeta potential, and morphology of each of the materials were determined. Aerosols of each material were generated using a dry powder aerosol generator and by nebulization of particle suspensions. The mass concentration of the particles in the inhalation atmosphere was determined gravimetrically and the particle size was determined using a cascade impactor, an optical particle counter, and a scanning mobility particle sizer. The dispersion techniques used generated fine aerosols with particle size distributions in the respiratory range. However, as a result of the significant agglomeration of nanoparticles in the test materials evaluated, no more than a few mass percent of the materials were present as single nanoparticles (i.e.,100 nm). Considering the number, a greater percentage of nanoparticles was present. Based on the obtained results and experience with the equipment, a technical setup for inhalation studies with nanomaterials is proposed. Furthermore, a stepwise testing approach is recommended that also could reduce the number of animals used in testing. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |