Evaluation of individual monitoring in mixed neutron/photon fields: Mid-term results from the EVIDOS project
Autor: | M. Coeck, Giorgio Curzio, H. Muller, C. Molinos, Filip Vanhavere, A. Fiechtner, J.-E. Kyllönen, Francesco D'Errico, V. Lacoste, M. Boschung, Helmut Schuhmacher, Marcel Reginatto, T. Lahaye, T. Bolognese-Milsztajn, David Bartlett, Lennart Lindborg, Richard Tanner, M. Luszik-Bhadra |
---|---|
Přispěvatelé: | Centre d'Etude de l'Energie Nucléaire (SCK-CEN), National Radiological Protection Board (NRPB), Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Paul Scherrer Institute (PSI), Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Physikalisch-Technische Bundesanstalt [Braunschweig] (PTB) |
Jazyk: | angličtina |
Rok vydání: | 2006 |
Předmět: |
medicine.medical_specialty
Nuclear engineering [SDV]Life Sciences [q-bio] radiation field dose calculation nuclear industry radiation detection Radiation Dosage Sensitivity and Specificity 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine Radiation Protection Neutron flux Radiation Monitoring medicine Dosimetry Radiology Nuclear Medicine and imaging Neutron Medical physics Research reactor European Union MOX fuel Physics Neutrons Photons Radiation Radiological and Ultrasound Technology Spectrometer Equivalent dose business.industry photon Public Health Environmental and Occupational Health article reference value Reproducibility of Results General Medicine Equipment Design neutron dosimetry Equipment Failure Analysis neutron radiation 030220 oncology & carcinogenesis radiation measurement radiation dose distribution nuclear reactor Radiation protection business radiation dose |
Zdroj: | RADIATION PROTECTION DOSIMETRY RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4), pp.263-267. ⟨10.1093/rpd/ncj011⟩ |
DOI: | 10.1093/rpd/ncj011⟩ |
Popis: | EVIDOS is an EC sponsored project that aims at an evaluation and improvement of radiation protection dosimetry in mixed neutron/photon fields. This is performed through spectrometric and dosimetric investigations during different measurement campaigns in representative workplaces of the nuclear industry. The performance of routine and, in particular, novel personal dosemeters and survey instruments is tested in selected workplace fields. Reference values for the dose equivalent quantities, H*(10) and Hp(10) and the effective dose E, are determined using different spectrometers that provide the energy distribution of the neutron fluence and using newly developed devices that determine the energy and directional distribution of the neutron fluence. The EVIDOS project has passed the mid-term, and three measurement campaigns have been performed. This paper will give an overview and some new results from the third campaign that was held in Mol (Belgium), around the research reactor VENUS and in the MOX producing plant of Belgonucléaire. © 2006 Oxford University Press. |