Intraoperative 3-dimensional imaging of scaphoid fracture reduction and fixation

Autor: Shai Luria, Meir Liebergall, Ori Safran, R. Mosheiff, G. Zinger
Rok vydání: 2015
Předmět:
Zdroj: Orthopaedics & Traumatology: Surgery & Research. 101(3):353-357
ISSN: 1877-0568
DOI: 10.1016/j.otsr.2014.07.038
Popis: Introduction We examined the clinical benefit of two intraoperative three-dimensional imaging modalities for reduction and fixation of scaphoid fractures. Hypothesis Our hypothesis was that three dimensional imaging will aid in operative care in comparison with standard fluoroscopy. Methods In 25 consecutive patients treated for fractures, after satisfactory reduction and fixation was obtained with a single Kirschner wire using fluoroscopy, intraoperative three-dimensional visualization was performed. The quality of fracture reduction, wire position and extrusion of the wire were examined. Results In two of the 25 cases, after three-dimensional visualization, malreduction of the fracture was seen and the reduction revised. Artifact and the dependency on technologist performance, limited the use of these modalities to locate the wire accurately. Discussion Diagnosis of malreduction of a scaphoid fracture is possible with 3-dimensional modalities. Utilization of these systems is still limited by technical factors. Level of evidence Level IV. Retrospective study.
Databáze: OpenAIRE