Ethambutol Is Cleared by a Contemporary High-Flux Hemodialyzer, and Drug Monitoring Ensures Safety and Therapeutic Effect

Autor: Peter J. Donovan, Kim Ta, Brett McWhinney, Rusheng Chew, Helen Healy, Sarah Jongbloed, Jacobus P.J. Ungerer, Marion L. Woods, Dev Jegatheesan
Rok vydání: 2016
Předmět:
Zdroj: Antimicrobial agents and chemotherapy. 61(6)
ISSN: 1098-6596
Popis: It is uncertain, given the lack of recent data and the inconclusive nature of previous data, whether ethambutol is cleared by hemodialysis using contemporary dialyzers. We measured serum ethambutol concentrations before, during, and 1 h after hemodialysis in a 75-year-old Caucasian man receiving ethambutol for disseminated Bacille Calmette-Guérin infection. There was a mean 41% decrease in serum ethambutol concentration during dialysis, confirming the hemodialyzability of ethambutol and the utility of drug monitoring in ensuring safety.
Databáze: OpenAIRE