Evaluation of retinal nerve fiber layer defect using wide-field en-face swept-source OCT images by applying the inner limiting membrane flattening

Autor: Hidetoshi Takahashi, Tetsuya Yuasa, Tsutomu Kikawa, Naoko Takada, Seri Takahashi, Koudai Kimura, Akiko Matsumoto, Kazuichi Maruyama, Kazuko Omodaka, Naoki Miura, Toru Nakazawa, Masahiro Akiba
Rok vydání: 2016
Předmět:
0301 basic medicine
Male
Retinal Ganglion Cells
Visual acuity
genetic structures
Eye Diseases
Vision
Nerve fiber layer
Visual Acuity
Glaucoma
lcsh:Medicine
Social Sciences
Diagnostic Radiology
chemistry.chemical_compound
0302 clinical medicine
Nerve Fibers
Animal Cells
Normal tension glaucoma
Medicine and Health Sciences
Psychology
Low Tension Glaucoma
lcsh:Science
Tomography
Neurons
Multidisciplinary
Radiology and Imaging
Middle Aged
Visual field
medicine.anatomical_structure
Female
Sensory Perception
medicine.symptom
Anatomy
Cellular Types
Tomography
Optical Coherence

Optic disc
Research Article
medicine.medical_specialty
Materials science
Ganglion Cells
Imaging Techniques
Ocular Anatomy
Research and Analysis Methods
Retina
Optic Disc
03 medical and health sciences
Ocular System
Diagnostic Medicine
Ophthalmology
medicine
Humans
Aged
Reproducibility
lcsh:R
Reproducibility of Results
Biology and Life Sciences
Afferent Neurons
Retinal
Cell Biology
medicine.disease
eye diseases
030104 developmental biology
chemistry
Cellular Neuroscience
030221 ophthalmology & optometry
Eyes
lcsh:Q
sense organs
Head
Neuroscience
Zdroj: PLoS ONE
PLoS ONE, Vol 12, Iss 10, p e0185573 (2017)
ISSN: 1932-6203
Popis: Purpose The assessment of retinal nerve fiber layer defects (RNFLDs) is a useful part of glaucoma care. Here, we obtained en-face images of retinal layers below the inner limiting membrane (ILM) with swept source-optical coherence tomography (SS-OCT), and measured RNFLD angle with new software. Methods This study included 105 eyes of 105 normal tension glaucoma (NTG) patients (age, 59.8 ± 13.2). Exclusion criteria were best-corrected visual acuity 28 mm, non-glaucoma ocular disease, and systemic disease affecting the visual field. We obtained 12 x 9 mm 3D volume scans centered on the macula with SS-OCT (DRI OCT-1, Topcon), and from these scans, created 3 averaged en-face images, each comprising 7 horizontal en-face images (total thickness: 18.2 μm). We labeled these averaged images, according to their depth below the ILM, as en-face images 1 (shallowest), 2 (middle) and 3 (deepest). In each image, a circle was drawn centered on the disc, with a radius of half the distance between the centers of the disc and macula. The investigator marked points where the edge of the RNFLD intersected this circle, and RNFLD angle (RNFLDA) was calculated with new software. Finally, we analyzed the association between RNFLDA, cpRNFLT, weighted RGC count (wrgc) and Humphrey field analyzer (HFA)-measured mean deviation (MD) and hemifield total deviation (TD), both overall and in each hemifield. Results En-face image 2 had the highest interclass reproducibility for measuring RNFLDA (intra-rater intraclass correlation coefficient (ICC): 0.988, inter-rater ICC: 0.962). The correlation coefficients with RNFLDA were: HFA MD, -0.60; superior TD, -0.73; inferior TD, -0.69; overall cpRNFLT, -0.27; superior hemifield cpRNFLT, -0.39; and inferior hemifield cpRNFLT, -0.53 (all p
Databáze: OpenAIRE