An evaluation of the cuff characteristics and incidence of laryngeal complications using a new nasotracheal tube in prolonged intubations

Autor: John G. Morgan, Tamotsu Shinozaki, Robert S. Deane
Rok vydání: 1977
Předmět:
Zdroj: The Journal of trauma. 17(4)
ISSN: 0022-5282
Popis: A series of 1,187 nasotracheal intubations, carried out from January 1973 to December, 1975, used a new tube. The design included a smooth tip, a cuff with a large area of contact, low pressure and a high residual volume, and a radiopaque line which is easily visible on chest X-ray. A secondary irrigating lumen opening distal to the cuff provides closed-system irrigation, measurement of airway pressures, and sampling of tracheal gases. In the 811 intubated nontracheostomized patients who survived, the overall incidence of significant laryngeal damage was 1%. In patients intubated in excess of 10 days the damage incidence was 10%, and we suggest that tracheostomy should be carried out at this time. No patients suffered from any known permanent laryngeal damage.
Databáze: OpenAIRE