Smartphone based blood pressure measurement: accuracy of the OptiBP mobile application according to the AAMI/ESH/ISO universal validation protocol
Autor: | Guillaume Bonnier, Virginie Durgnat, Jean-François Knebel, Gregory Hofmann, Arlene Ghajarzadeh-Wurzner, Jean Degott, Mathieu Lemay, Burnier Michel, Urvan Christen, Patrick Schoettker, Martin Proença, Alia Lemkaddem, Grégoire Wuerzner |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
medicine.medical_specialty
Acceptance rate Population cuffless Assessment and Diagnosis smartphone Medical instrumentation Internal Medicine medicine Humans education Advanced and Specialized Nursing Protocol (science) validation education.field_of_study Hypertension clinic business.industry blood pressure Blood Pressure Determination General Medicine Reference Standards University hospital international standards Mobile Applications Blood Pressure Monitors Blood pressure optical signal Hypertension Physical therapy Cardiology and Cardiovascular Medicine business Blood Pressure Hypertension/diagnosis Smartphone Devices and Technology application |
Zdroj: | Blood Pressure Monitoring Blood pressure monitoring, vol. 26, no. 6, pp. 441-448 |
ISSN: | 1473-5725 1359-5237 |
Popis: | Objective The aim of this study was to assess the accuracy of the OptiBP mobile application based on an optical signal recorded by placing the patient's fingertip on a smartphone's camera to estimate blood pressure (BP). Measurements were carried out in a general population according to existing standards of the Association for the Advancement of Medical Instrumentation (AAMI), the European Society of Hypertension (ESH) and the International Organization for Standardization (ISO). Methods Participants were recruited during a scheduled appointment at the hypertension clinic of Lausanne University Hospital in Switzerland. Age, gender and BP distribution were collected to fulfill AAMI/ESH/ISO universal standards. Both auscultatory BP references and OptiBP were measured and compared using the opposite arm simultaneous method as described in the 81060-2:2018 ISO norm. Results A total of 353 paired recordings from 91 subjects were analyzed. For validation criterion 1, the mean ± SD between OptiBP and reference BP recordings was respectively 0.5 ± 7.7 mmHg and 0.4 ± 4.6 mmHg for SBP and DBP. For validation criterion 2, the SD of the averaged BP differences between OptiBP and reference BP per subject was 6.3 mmHg and 3.5 mmHg for SBP and DBP. OptiBP acceptance rate was 85%. Conclusion The smartphone embedded OptiBP cuffless mobile application fulfills the validation requirements of AAMI/ESH/ISO universal standards in a general population for the measurement of SBP and DBP. |
Databáze: | OpenAIRE |
Externí odkaz: |