Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE)
Autor: | Susan Chrolavicius, Michael Glikson, Fredrik Gadler, Jörg Neuzner, Xavier Viñolas, Jim Gilkerson, Stuart J. Connolly, Janice Pogue, Lieselot VanErven, Kenneth M. Stein, Gilles O'Hara, Thierry Pochet, Stefan H. Hohnloser, Ursula Appl, Josef Kautzner, P. Mabo, Bernard Thibault, Brandi Meeks, Csaba Foldesi, Béla Merkely, Jeff S. Healey |
---|---|
Přispěvatelé: | Goethe University Hospital, Laboratoire Traitement du Signal et de l'Image (LTSI), Université de Rennes 1 (UR1), Université de Rennes (UNIV-RENNES)-Université de Rennes (UNIV-RENNES)-Institut National de la Santé et de la Recherche Médicale (INSERM), CIC-IT Rennes, Hôpital Pontchaillou-Institut National de la Santé et de la Recherche Médicale (INSERM), Service de cardiologie et maladies vasculaires [Rennes] = Cardiac, Thoracic, and Vascular Surgery [Rennes], CHU Pontchaillou [Rennes], Population Health Research Institute, Université de Rennes (UR)-Institut National de la Santé et de la Recherche Médicale (INSERM) |
Rok vydání: | 2015 |
Předmět: |
Male
medicine.medical_specialty Defibrillation [SDV]Life Sciences [q-bio] medicine.medical_treatment Population Electric Countershock Ventricular tachycardia Risk Assessment law.invention Prosthesis Implantation Postoperative Complications Randomized controlled trial law Medicine Humans Single-Blind Method education Fibrillation Heart Failure education.field_of_study business.industry Hazard ratio Arrhythmias Cardiac General Medicine Middle Aged medicine.disease Prognosis 3. Good health Surgery Defibrillators Implantable Transplantation Anesthesia Ventricular fibrillation Ventricular Fibrillation Female Patient Safety medicine.symptom business |
Zdroj: | Lancet Lancet, Elsevier, 2015, 385 (9970), pp.785-91. ⟨10.1016/S0140-6736(14)61903-6⟩ The Lancet The Lancet, 2015, 385 (9970), pp.785-91. ⟨10.1016/S0140-6736(14)61903-6⟩ |
ISSN: | 1474-547X 0080-0384 0140-6736 |
Popis: | International audience; Defibrillation testing by induction and termination of ventricular fibrillation is widely done at the time of implantation of implantable cardioverter defibrillators (ICDs). We aimed to compare the efficacy and safety of ICD implantation without defibrillation testing versus the standard of ICD implantation with defibrillation testing. In this single-blind, randomised, multicentre, non-inferiority trial (Shockless IMPLant Evaluation [SIMPLE]), we recruited patients aged older than 18 years receiving their first ICD for standard indications at 85 hospitals in 18 countries worldwide. Exclusion criteria included pregnancy, awaiting transplantation, particpation in another randomised trial, unavailability for follow-up, or if it was expected that the ICD would have to be implanted on the right-hand side of the chest. Patients undergoing initial implantation of a Boston Scientific ICD were randomly assigned (1:1) using a computer-generated sequence to have either defibrillation testing (testing group) or not (no-testing group). We used random block sizes to conceal treatment allocation from the patients, and randomisation was stratified by clinical centre. Our primary efficacy analysis tested the intention-to-treat population for non-inferiority of no-testing versus testing by use of a composite outcome of arrhythmic death or failed appropriate shock (ie, a shock that did not terminate a spontaneous episode of ventricular tachycardia or fibrillation). The non-inferiority margin was a hazard ratio (HR) of 1·5 calculated from a proportional hazards model with no-testing versus testing as the only covariate; if the upper bound of the 95% CI was less than 1·5, we concluded that ICD insertion without testing was non-inferior to ICD with testing. We examined safety with two, 30 day, adverse event outcome clusters. The trial is registered with ClinicalTrials.gov, number NCT00800384. Between Jan 13, 2009, and April 4, 2011, of 2500 eligible patients, 1253 were randomly assigned to defibrillation testing and 1247 to no-testing, and followed up for a mean of 3·1 years (SD 1·0). The primary outcome of arrhythmic death or failed appropriate shock occurred in fewer patients (90 [7% per year]) in the no-testing group than patients who did receive it (104 [8% per year]; HR 0·86, 95% CI 0·65-1·14; pnon-inferiority |
Databáze: | OpenAIRE |
Externí odkaz: |