Spatially Resolved Determination of Metallization-Induced Recombination Losses Using Photoluminescence Imaging
Autor: | Andreas Wolf, David R. C. Falconi, Sabrina Lohmüller, David Herrmann, Andreas Fell, Daniel Ourinson, Andreas Brand, Hannes Höffler |
---|---|
Přispěvatelé: | Publica |
Rok vydání: | 2021 |
Předmět: |
Materials science
Photoluminescence Field (physics) 02 engineering and technology 01 natural sciences Signal Molecular physics law.invention law 0103 physical sciences Solar cell Dotierung und Diffusion Electrical and Electronic Engineering Sheet resistance solar cell metallization Common emitter 010302 applied physics Homogeneity (statistics) Carrier lifetime 021001 nanoscience & nanotechnology Condensed Matter Physics Electronic Optical and Magnetic Materials Silicium-Photovoltaik Photovoltaik photoluminescence 0210 nano-technology |
Zdroj: | IEEE Journal of Photovoltaics. 11:174-184 |
ISSN: | 2156-3403 2156-3381 |
DOI: | 10.1109/jphotov.2020.3038336 |
Popis: | Metallization induced recombination losses are one dominant loss mechanism for current industrial solar cells. A precise determination of these losses is important for contacting technology optimization, as well as precise solar cell modeling. Usually, for state-of-the-art approaches to determine j 0,met, it is assumed that the samples itself exhibit spatially uniform properties (e.g., carrier lifetime or sheet resistance) or that the used reference samples are identical to the metallized samples. Finally, in most cases, only one global j 0,met-value for the entire sample is given, neglecting possible spatial inhomogeneities. In this article, we mostly eliminate the necessity for the assumptions of perfect sample homogeneity by means of an interpolation scheme of the photoluminescence (PL) signal. Thereby, we can predict the PL signal of a virtually nonmetallized test field with a relative standard deviation of about σ a 0.7%. Additionally, we determine j 0,met for specific test fields at different positions on the sample and correlate the results to the local emitter sheet resistance R sh, the local peak firing temperature of the sample during the fast firing process T peak, and the test field finger spacing d . For our samples, a reduction of d from d = 1000 μm to d = 200 μm leads to a reduction of j 0,met by up to 18%. This strong effect is physically unexpected and so far not considered by the state-of-the-art approach, frequently performed in the photovoltaic community. Further, we perform a sensitivity and error analysis which reveals that we are able to determine j 0,met within an estimated accuracy between 15% and 18%. |
Databáze: | OpenAIRE |
Externí odkaz: |