Autologous Blood for Conjunctival Autograft Fixation in Primary Pterygium Surgery: A Systematic Review and Meta-analysis
Autor: | Hossam Zein, Ahmed Negida, Basma Muhammad Muhammad, Fathy Assaf, Ammar Ismail, Ahmed Elsehili, Mohamed Abdelmongy, Sherif B. Elsherif, Shin Yamane, Mohamed M. Abdel-Daim, Ahmad Hassanen, Kazuaki Kadonosono |
---|---|
Rok vydání: | 2018 |
Předmět: |
Pharmacology
medicine.medical_specialty business.industry medicine.disease Pterygium Surgery law.invention Patient satisfaction Randomized controlled trial Suture (anatomy) law Relative risk Meta-analysis Drug Discovery Medicine Humans business Fibrin glue Autografts Conjunctiva Fixation (histology) Randomized Controlled Trials as Topic |
Zdroj: | Current pharmaceutical design. 24(35) |
ISSN: | 1873-4286 |
Popis: | Objective: The study aimed to perform a systematic review and meta-analysis of randomized controlled trials comparing the efficacy and complications of autologous blood versus using fibrin glue and surgical sutures for conjunctival autograft fixation in primary pterygium surgery. Design: Systematic review with quantitative meta-analysis. Methods: Four authentic databases have been searched using relevant keywords. Eligible studies were obtained, and their data were extracted into an online form. Analysis was done using Review Manager for windows. Dichotomous outcomes were reported as risk ratio, while continuous data were reported as mean difference. Results: Seven studies were included in the analysis. Most of the included studies were of moderate quality according to Cochrane Risk of Bias assessment tool. There was no difference between the three techniques in recurrence rates (Risk Ratio (RR) 0.80, 95% CI [0.45 to 1.44], p= 0.46). Graft retraction and displacement were more profound in the autologous blood group vs fibrin glue and suture groups (RR 3.22, 95% CI [1.48 to7.02], p= 0.003) and (RR 5.27, 95% CI [2.24 to 12.38], p> 0.001) respectively. In terms of operative time, fibrin glue took shorter while suturing took longer time compared to blood coagulum (Mean Difference (MD) =1.57, 95% CI [0.90, 2.25], p> 0.00001) and (MD -20.47, 95% CI [-38.05 to -2.88], p =0.02). Conclusion: Autologous blood for conjunctival autograft fixation in primary pterygium surgery was associated with lower graft stability than fibrin glue or sutures. However, it did not account for higher recurrence rates than the fibrin glue or sutures. Patient satisfaction and postoperative symptoms are relatively better in the blood coagulum group than the other techniques. The overall quality of evidence is low. Further well designed randomized controlled trials are still needed. |
Databáze: | OpenAIRE |
Externí odkaz: |