Assessing a National Collaborative Program To Prevent Catheter-Associated Urinary Tract Infection in a Veterans Health Administration Nursing Home Cohort
Autor: | Tina Martin, Barbara W. Trautner, Karen E. Fowler, Beth J. King, Gary A. Roselle, Sanjay Saint, Stephen M. Kralovic, Deborah Welsh, Marla Clifton, David Ratz, M. Todd Greene, Sarah L. Krein, Lona Mody |
---|---|
Rok vydání: | 2018 |
Předmět: |
Microbiology (medical)
medicine.medical_specialty Epidemiology Urinary system MEDLINE Urine 030501 epidemiology Rate ratio Cohort Studies 03 medical and health sciences 0302 clinical medicine Surveys and Questionnaires medicine Humans Infection control 030212 general & internal medicine Cooperative Behavior Veterans Cross Infection Infection Control business.industry United States Confidence interval Nursing Homes United States Department of Veterans Affairs Catheter Interinstitutional Relations Infectious Diseases Catheter-Related Infections Urinary Tract Infections Emergency medicine Cohort Regression Analysis Urinary Catheterization 0305 other medical science business Cohort study |
Zdroj: | Infection Control & Hospital Epidemiology. 39:820-825 |
ISSN: | 1559-6834 0899-823X |
DOI: | 10.1017/ice.2018.99 |
Popis: | OBJECTIVECollaborative programs have helped reduce catheter-associated urinary tract infection (CAUTI) rates in community-based nursing homes. We assessed whether collaborative participation produced similar benefits among Veterans Health Administration (VHA) nursing homes, which are part of an integrated system.SETTINGThis study included 63 VHA nursing homes enrolled in the “AHRQ Safety Program for Long-Term Care,” which focused on practices to reduce CAUTI.METHODSChanges in CAUTI rates, catheter utilization, and urine culture orders were assessed from June 2015 through May 2016. Multilevel mixed-effects negative binomial regression was used to derive incidence rate ratios (IRRs) representing changes over the 12-month program period.RESULTSThere was no significant change in CAUTI among VHA sites, with a CAUTI rate of 2.26 per 1,000 catheter days at month 1 and a rate of 3.19 at month 12 (incidence rate ratio [IRR], 0.99; 95% confidence interval [CI], 0.67–1.44). Results were similar for catheter utilization rates, which were 11.02% at month 1 and 11.30% at month 12 (IRR, 1.02; 95% CI, 0.95–1.09). The numbers of urine cultures per 1,000 residents were 5.27 in month 1 and 5.31 in month 12 (IRR, 0.93; 95% CI, 0.82–1.05).CONCLUSIONSNo changes in CAUTI rates, catheter use, or urine culture orders were found during the program period. One potential reason was the relatively low baseline CAUTI rate, as compared with a cohort of community-based nursing homes. This low baseline rate is likely related to the VHA’s prior CAUTI prevention efforts. While broad-scale collaborative approaches may be effective in some settings, targeting higher-prevalence safety issues may be warranted at sites already engaged in extensive infection prevention efforts.Infect Control Hosp Epidemiol 2018;820–825 |
Databáze: | OpenAIRE |
Externí odkaz: |