Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty

Autor: Jean-Paul Carret, Christophe Chevillotte, Vincent Pibarot, Jacques Bejui-Hugues, Olivier Guyen
Přispěvatelé: Laboratoire de Biomécanique et Mécanique des Chocs (LBMC UMR T9406), Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Université de Lyon-Institut Français des Sciences et Technologies des Transports, de l'Aménagement et des Réseaux (IFSTTAR), Département de Chirurgie Orthopédique, Hospices Civils de Lyon (HCL)-Hôpital Edouard Herriot [CHU - HCL], Hospices Civils de Lyon (HCL)-Affiliation nécessaire...
Rok vydání: 2010
Předmět:
Male
Ceramics
Time Factors
Osteolysis
Arthroplasty
Replacement
Hip

Health Status
Biocompatible Materials
Severity of Illness Index
Osteoarthritis
Hip

Disability Evaluation
0302 clinical medicine
Orthopedics and Sports Medicine
030212 general & internal medicine
Cementation
030222 orthopedics
Calcar
Middle Aged
[SPI.MECA]Engineering Sciences [physics]/Mechanics [physics.med-ph]
Prosthesis Failure
3. Good health
surgical procedures
operative

Current practice
Radiological weapon
Female
Hip Joint
Total hip arthroplasty
Adult
musculoskeletal diseases
medicine.medical_specialty
Prosthesis Design
Young Adult
03 medical and health sciences
medicine
Humans
Aged
Retrospective Studies
Original Paper
business.industry
Retrospective cohort study
Recovery of Function
medicine.disease
Surgery
Radiography
Harris Hip Score
Orthopedic surgery
Hip Prosthesis
business
[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
Follow-Up Studies
Zdroj: International Orthopaedics
International Orthopaedics, Springer Verlag, 2011, 35 (11), pp. 1599-1604. ⟨10.1007/s00264-010-1185-3⟩
ISSN: 1432-5195
0341-2695
DOI: 10.1007/s00264-010-1185-3
Popis: The aim of this study was to evaluate the first 100 cementless ceramic-on-ceramic total hip arthroplasty (THA) performed at our institution with more than nine years of follow-up. Clinical evaluation was performed using Harris hip score. Radiological evaluation was performed by two surgeons. Four patients were lost to follow-up. Harris hip score significantly improved at latest follow-up. Radiological analysis showed calcar osteolysis for 75 patients and one cup loosening. One patient required a revision five years postoperatively for cup loosening. Based on these results and the routine use of a navigation system to optimise positioning of the implants, we advocate the use of uncemented hydroxyapatite coated ceramic-on-ceramic THA in young and active patients in our current practice.
Databáze: OpenAIRE