Complications associated with left ventricular puncture
Autor: | Allison K. Cabalka, Charanjit S. Rihal, Sridevi R. Pitta |
---|---|
Rok vydání: | 2010 |
Předmět: |
Adult
Male Cardiac Catheterization medicine.medical_specialty Percutaneous Heart Ventricles Minnesota medicine.medical_treatment Heart Valve Diseases Hemodynamics Hemorrhage Punctures Radiography Interventional Risk Assessment Risk Factors medicine Humans Radiology Nuclear Medicine and imaging Paravalvular leak Aged Retrospective Studies Cardiac catheterization Aged 80 and over Heart Valve Prosthesis Implantation Hemothorax Hemostatic Techniques business.industry Equipment Design General Medicine Middle Aged medicine.disease Surgery Echocardiography Hemostasis Access site Female Cardiology and Cardiovascular Medicine business Complication |
Zdroj: | Catheterization and Cardiovascular Interventions. 76:993-997 |
ISSN: | 1522-1946 |
DOI: | 10.1002/ccd.22640 |
Popis: | Objective: To report complications in a consecutive series of patients undergoing percutaneous left ventricular apical puncture (LVAP) and sheath placement for diagnostic or interventional procedures. Background: Percutaneous LVAP is only rarely used to provide hemodynamic data in the presence of mechanical prosthetic valves. Recently, LVAP has been used to facilitate complex interventional procedures such as paravalvular leak closures. These frequently necessitate placement of 4–6 F sheaths, rather than smaller needles. Optimal technique and outcomes are largely unknown for this uncommon procedure. Methods: We retrospectively analyzed 32 patients undergoing LVAP with echocardiographic and fluoroscopic guidance at our institution between 2002 and 2009. These patients were referred to the cardiac catheterization laboratory for hemodynamic assessment to rule out prosthetic dysfunction and or to facilitate paravalvular leak closure. Sheaths ranged from 4 to 6 F were removed at the end of the procedure after reversing any anticoagulation. No specific closure devices were used for hemostasis. Frequency of access site complications associated with LVAP recorded. Results: Apical access site related complications were higher in patients requiring LVAP for intervention than for diagnostic purposes (25% vs. 12.5%). Hemothorax was the most frequent serious complication occurring in 6 (19%) patients and frequently required intervention 5(16%). Three patients had local bleeding with no drop in hemoglobin or need for intervention. Conclusions: LVAP is associated with a significant incidence of access-related complications. There is a need for safe and reliable methods of closing percutaneous LVAP access sites. © 2010 Wiley-Liss, Inc. |
Databáze: | OpenAIRE |
Externí odkaz: |