Development of a unique retractor for performing endoscopic pituitary surgery-EASYTRAC
Autor: | Kirandeep Kaur, P. Sarat Chandra |
---|---|
Rok vydání: | 2019 |
Předmět: |
Adenoma
Male medicine.medical_specialty Adolescent Endoscope Pituitary Diseases Vomer 030218 nuclear medicine & medical imaging Single nostril Craniopharyngioma 03 medical and health sciences 0302 clinical medicine medicine Humans Pituitary Neoplasms business.industry Equipment Design Surgical Instruments Surgery Smooth surface Retractor Deviated nasal septum medicine.anatomical_structure Neurology Pituitary Gland Neuroendoscopy Neurology (clinical) Pituitary surgery business Keel (bird anatomy) 030217 neurology & neurosurgery |
Zdroj: | Neurology India. 67:1509 |
ISSN: | 0028-3886 |
DOI: | 10.4103/0028-3886.273609 |
Popis: | Background: A unique self-expanding retractor (EASYTRAC®) is described, which provides several advantages for endoscopic pituitary surgery-enhanced visualization, creating more space, reducing the mucosal damage, and enhancing the nasal quality of life (QoF). Presented here is the proof of concept. Methods: EASYTRAC® is made of an aircraft-grade, SS-titanium alloy to provide optimal opening strength with a low profile (0.5 mm thick). It has a nonreflective, smooth surface finish. Patented design and wire pulling method of the EASYTRAC® makes it easy to insert and deploy. EASYTRAC® is inserted through the submucosal tunnel using a small, unilateral mucocutaneous incision. Following this, the ring attached to the wire is pulled out to deploy the retractor. This provides expansion of the retractor leading to fracture of the septum to one side at the keel of the vomer. The rest of the surgery is performed in the standard manner using an endoscope. The retractor is a single-use, disposable instrument and available in three different sizes. Results: Five endoscopic endonasal surgeries have been performed using the EASYTRAC®(four pituitary adenomas, one craniopharyngioma). Deviated nasal septum (DNS) was present in two of the surgeries. All surgeries were approached through the right mucoseptal corridor, and presence of DNS did not reduce exposure ( Conclusion: Retractor seems to be safe, easy to use, and effective. The surgeon's capabilities are enhanced by the retractor's dynamicity, minimal fogging of scope, minimal trauma to the mucosa, and adequate space to allow the introduction of three instruments through a single nostril. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |