Avoidance of Coronary Sinus Injury During Retrograde Cardioplegia

Autor: Takashi Fukutomi, Hideaki Nishimori, Miwa Tashiro, Kazuki Kihara, Nobuo Kondo, Kohei Miyashita, Kazumasa Orihashi, Nobuyuki Hirose, Masaki Yamamoto
Rok vydání: 2016
Předmět:
Zdroj: The Annals of thoracic surgery. 102(6)
ISSN: 1552-6259
Popis: Coronary sinus injury is a rare but critical complication of retrograde cardioplegia. Even after detection, successful repair with a pericardial patch is not always attained. Malalignment of the infusion cannula relative to the coronary sinus is likely to be partially responsible for the injury. Monitoring the location of the cannula tip can help prevent injury. Transesophageal echocardiography can indicate the vascular structure within which the cannula is located. This finding may be useful in preventing injury to the coronary sinus or middle cardiac vein.