Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study
Autor: | Per Blomström, Carina Blomström-Lundqvist, Stefan Lönnerholm, Helena Malmborg |
---|---|
Rok vydání: | 2013 |
Předmět: |
Male
medicine.medical_specialty Time Factors medicine.medical_treatment Ablation of atrial fibrillation Catheter ablation Cryosurgery Cardiac Catheters Pulmonary vein law.invention Randomized controlled trial law Physiology (medical) Internal medicine Atrial Fibrillation medicine Humans Aged Sweden business.industry Pulmonary vein ablation Atrial fibrillation Middle Aged medicine.disease Ablation Surgery Catheter Treatment Outcome Pulmonary Veins Fluoroscopy Catheter Ablation Quality of Life cardiovascular system Cardiology Female Cardiology and Cardiovascular Medicine business Follow-Up Studies |
Zdroj: | Europace. 15:1567-1573 |
ISSN: | 1532-2092 1099-5129 |
DOI: | 10.1093/europace/eut104 |
Popis: | The urge to facilitate the atrial fibrillation (AF) ablation procedure has led to the development of new ablation catheters specifically designed as 'one-shot tools' for pulmonary vein isolation (PVI). The purpose of this study was to compare the efficacy, safety, and procedure times for two such catheters using different energy sources.One hundred and ten patients, referred for ablation of paroxysmal or persistent AF, were randomized to treatment with either the cryoballoon or the circular multipolar duty-cycled radiofrequency-based pulmonary vein ablation catheter (PVAC). Complete PVI was achieved in 98 vs. 93% patients in the cryoballoon and PVAC group, respectively, with complication rates of 8 vs. 2% (P = 0.2). Complete freedom from AF, without antiarrhythmic drugs, after one single ablation procedure was seen in 46% in the cryoballoon vs. 34% after 12 months (P = 0.2). Procedure times were comparable, but fluoroscopy time was shorter for the cryoballoon (32 ± 16 min) than for the PVAC procedures (47 ± 17 min) (P0.001). A significant improvement of quality of life (QoL) and arrhythmia-related symptoms was seen in both groups after ablation.Both catheters proved comparably effective and safe in achieving acute PVI, apart from the shorter fluoroscopy times achieved with the cryoballoon. At follow-up, there was no statistically significant difference between the groups regarding freedom from AF and clinical success. The QoL increased to the same levels as for the general Swedish population in both groups. |
Databáze: | OpenAIRE |
Externí odkaz: |