Endovascular Stent Placement of Juxtaanastomotic Stenosis in Native Arteriovenous Fistula After Unsuccessful Balloon Angioplasty
Autor: | Utku Mahir Yıldırım, Özgur Özen, Cuneyt Aytekin, Durmus Güngör, Burak Ozkan, Ali Harman |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2013 |
Předmět: |
Vascular Fistula
medicine.medical_specialty Percutaneous business.industry Fistula medicine.medical_treatment Endovascular Procedures Angioplasty Arteriovenous fistula medicine.disease Balloon Surgery Stenosis Vascular & Interventional Radiology medicine Radiology Nuclear Medicine and imaging Radiology Hemodialysis business |
Zdroj: | Iranian Journal of Radiology |
ISSN: | 2008-2711 1735-1065 |
Popis: | Background In hemodialysis patients, the most common problem in arteriovenous fistulas, as the best functional vascular access, is the juxtaanastomotic located lesions. Percutaneous transluminal angioplasty is accepted as the treatment method for juxtanastomotic lesions. Objectives To assess juxtaanastomotic stent placement after insufficient balloon angioplasty in the treatment of autogenous radiocephalic or brachiocephalic fistula dysfunction. Patients and Methods Between July 2003 and June 2010, 20 hemodialysis patients with autogenous radiocephalic or brachiocephalic fistula dysfunction underwent stent placement for the lesion located at the juxtaanastomotic region. Indications for stent placement were insufficient balloon dilatation, early recurring stenosis, chronic organizing thrombus and vessel rupture. The Kaplan-Meier method was used to calculate the stent patency rates. All patients who had fistula dysfunction (thrombosis of hemodialysis access, difficult access cannulation, extremity pain due to thrombosis or decreased arterial access blood flow) were evaluated by color Doppler ultrasound. The stenoses were initially dilated with standard noncompliant balloons (3 to 10-mm in diameter). Dilatation was followed by high pressure (Blue Max, Boston Scientific) or cutting balloons (Boston Scientific), if the standard balloon failed to dilate the stenotic segment. Results Twenty-one stents were applied. The anatomical and clinical success rate was 100%. Seventeen additional interventions were done for 11 (55%) patients due to stent thrombosis or stenosis during follow-up. Our 1- and 2-year secondary patency rates were 76.2% and 65.5%, respectively and were comparable to those after balloon angioplasty and surgical shunt revision. Conclusion Metallic stent placement is a safe and effective procedure for salvage of native hemodialysis fistula after unsuccessful balloon angioplasty. |
Databáze: | OpenAIRE |
Externí odkaz: |