Autor: Marc W. Gerdisch, T. Brett Reece, Dominic Emerson, Richard S. Downey, Geoffrey B. Blossom, Arun Singhal, Joshua N. Baker, Theodor J.M. Fischlein, Vinay Badhwar, Alfredo Trento, Joanna Chikwe, Lawrence M. Wei, Jason P. Glotzbach, Timothy W. James, Reed D. Quinn, J. Alan Wolfe, Kentaro Yamane, Jeffrey T. Cope, Behzad Solemani, Hiroo Takayama, Victor M. Rodriguez, Takashi Murashita, Rochus K. Voeller, Ming-Sing Si, Melissa Levack, Chris R. Burke, Marc R. Moon, Alexander Kraev, Marek J. Jasinski, Georgios Stavridis, J. Scott Rankin
Rok vydání: 2022
Předmět:
Zdroj: JTCVS Techniques. 14:55-65
ISSN: 2666-2507
Popis: Geometric ring annuloplasty has shown promise during bicuspid aortic valve repair for aortic insufficiency. This study examined early outcomes of bicuspid aortic valve repair associated with proximal aortic aneurysm replacement.From September 2017 to November, 2021, 127 patients underwent bicuspid aortic valve repair with concomitant proximal aneurysm reconstruction. Patient age was 50.6 ± 12.7 years (mean ± standard deviation), male gender was 83%, New York Heart Association Class was 2 (1-2) (median [interquartile range]), and preoperative aortic insufficiency grade was 3 (2-4). Ascending aortic diameter was 50 (46-54) mm, and all patients had ascending aortic replacement. Forty patients had sinus diameters greater than 45 mm, prompting remodeling root procedures. A total of 105 patients had Sievers type 1 valves, 3 patients had type 0, and 7 patients had type 2. A total of 118 patients had primarily right/left fusion, 8 patients had right/nonfusion, and 1 patient had left/nonfusion. Leaflet reconstruction used central leaflet plication and cleft closure, with limited ultrasonic decalcification in 31 patients.Ring size was 23 (21-23) mm, and 26 of 40 root procedures were selective nonfused sinus replacements. Aortic clamp time was 139 (112-170) minutes, and bypass time was 178 (138-217) minutes. Postrepair aortic insufficiency grade was 0 (0-0) (Geometric ring annuloplasty for bicuspid aortic valve repair with proximal aortic aneurysm reconstruction is safe and associated with good early outcomes. Further experience and follow-up will help inform long-term durability.
Databáze: OpenAIRE