Evaluation and commissioning of a surface based system for respiratory sensing in 4D CT
Autor: | George T.Y. Chen, Guido Baroni, Maria Francesca Spadea, Gregory C. Sharp, J Turcotte, David P. Gierga |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2010 |
Předmět: |
Scanner
Respiratory-Gated Imaging Techniques Time Factors respiratory motion Computer science Synchronizing Phase detector Sensitivity and Specificity Imaging phantom Particle detector Motion Imaging Three-Dimensional surface imaging Calibration Humans Radiation Oncology Physics Radiology Nuclear Medicine and imaging Computer vision multi sensor analysis Four-Dimensional Computed Tomography Instrumentation Ground truth Radiation business.industry Phantoms Imaging 3D reconstruction Reproducibility of Results 4D CT Respiratory Mechanics Artificial intelligence business Nuclear medicine Artifacts |
Zdroj: | Journal of Applied Clinical Medical Physics |
ISSN: | 1526-9914 |
Popis: | The purpose of this study is to assess the temporal and reconstruction accuracy of a surface imaging system, the GateCT under ideal conditions, and compare the device with a commonly used respiratory surrogate: the Varian RPM. A clinical CT scanner, run in cine mode, was used with two optical devices, GateCT and RPM, to detect respiratory motion. A radiation detector, GM‐10, triggers the X‐ray on/off to GateCT system, while the RPM is directly synchronized with the CT scanner through an electronic connection. Two phantoms were imaged: the first phantom translated on a rigid plate along the anterior–posterior (AP) direction, and was used to assess the temporal synchronization of each optical system with the CT scanner. The second phantom, consisting of five spheres translating 3 cm peak‐to‐peak in the superior–inferior direction, was used to assess the quality of rebinned images created by GateCT and RPM. Calibration assessment showed a nearly perfect synchronization with the scanner for both the RPM and GateCT systems, thus demonstrating the good performance of the radiation detector. Results for the volume rebinning test showed discrepancies in volumes for the 3D reconstruction (compared to ground truth) of up to 36% for GateCT and up to 40% for RPM. No statistical difference was proven between the two systems in volume sorting. Errors are mainly due to phase detection inaccuracies and to the large motion of the phantom. This feasibility study assessed the consistency of two optical systems in synchronizing the respiratory signal with the image acquisition. A new patient protocol based on both RPM and GateCT will be soon started. PACS number: 87 |
Databáze: | OpenAIRE |
Externí odkaz: |