Myocardial blood flow and myocardial flow reserve values in 13N–ammonia myocardial perfusion PET/CT using a time-efficient protocol in patients without coronary artery disease
Autor: | Cornel Jh, Opstal Tsj, van der Zant Fm, Wondergem M, Knol Rjj |
---|---|
Rok vydání: | 2018 |
Předmět: |
lcsh:Medical physics. Medical radiology. Nuclear medicine
Stress flow medicine.medical_specialty lcsh:R895-920 medicine.medical_treatment Biophysics 030204 cardiovascular system & hematology Revascularization 030218 nuclear medicine & medical imaging Coronary artery disease 03 medical and health sciences 0302 clinical medicine Myocardial PET/CT Internal medicine Computer Science (miscellaneous) medicine Radiology Nuclear Medicine and imaging Cardiac imaging Flow reserve PET-CT medicine.diagnostic_test business.industry Time-efficient protocol Blood flow medicine.disease Time efficient Residual activity correction Positron emission tomography Cardiology 13 N–ammonia Molecular Medicine business Perfusion circulatory and respiratory physiology |
Zdroj: | European Journal of Hybrid Imaging, Vol 2, Iss 1, Pp 1-11 (2018) |
ISSN: | 2510-3636 |
DOI: | 10.1186/s41824-018-0029-z |
Popis: | Background Cardiac imaging by means of myocardial Positron Emission Tomography/Computed Tomography (PET/CT) is being used increasingly to assess coronary artery disease, to guide revascularization decisions with more accuracy, and it allows robust quantitative analysis of both regional myocardial blood flow (MBF) and myocardial flow reserve (MFR). Recently, a more time-efficient protocol has been developed in combination with a residual activity correction algorithm in which a stress acquisition is performed directly after completion of the rest acquisition to subtract remaining myocardial radioactivity. The objective of this study is to define flow values of myocardial blood flow (MBF) and Myocardial Flow Reserve (MFR) with 13N–ammonia (13NH3) myocardial perfusion PET/CT on patients without coronary artery disease using a time-efficient protocol, since reference values for this particular type of study are lacking in literature. In addition, we aim to determine the effect of the residual activity correction algorithm in this time-efficient protocol. Results A mean MBF in rest of 1.02 ± 0.22 ml/g/min, a mean MBF in stress of 2.54 ± 0.41 ml/g/min with a mean MFR of 2.60 ± 0.61 were measured. Female patients had a significant higher MBF in rest and stress, but lower MFR; a small but significant negative correlation was measured between age and MBF in stress and MFR. Residual activity correction had a significant effect resulting in a difference in global stress MBF before and after correction of 0.39 ± 0.13 ml/g/min. Conclusions This study established flow values for 13NH3 myocardial PET/CT with a time-efficient protocol, and established that MBF in stress corrected for residual activity is comparable with known reference values in normal studies without temporal overlap. Further validation of the technique could be of value, e.g. by comparison to standard imaging without temporal overlap, or validation against catheterization results. |
Databáze: | OpenAIRE |
Externí odkaz: |