Comparison of 2 interferometers for predicting visual acuity in patients with cataract
Autor: | B L Halliday, J E Ross |
---|---|
Rok vydání: | 1983 |
Předmět: |
medicine.medical_specialty
Visual acuity genetic structures Light medicine.medical_treatment Visual Acuity Cataract Extraction Cataract Cellular and Molecular Neuroscience chemistry.chemical_compound Cataracts Ophthalmology medicine Humans In patient Vision test Aged Retina business.industry Vision Tests Retinal Cataract surgery Middle Aged medicine.disease Snellen visual acuity Sensory Systems eye diseases medicine.anatomical_structure Interferometry chemistry Optometry sense organs medicine.symptom business Research Article |
Zdroj: | The British journal of ophthalmology. 67(5) |
ISSN: | 0007-1161 |
Popis: | Two clinical interferometers generated gratings directly on to the retina in young experienced observers and also in patients about to undergo cataract surgery. Eyes in the patients with no media opacities were used as controls. We agreed with the manufacturers' claims that gratings are seen on the retina independent of refractive state and that gratings can still be seen through most cataracts. However, we did not find that preoperative retinal visual acuity was of any value in predicting postoperative Snellen visual acuity. Reasons for this are discussed. |
Databáze: | OpenAIRE |