Comparison of different invasive hemodynamic methods for AV delay optimization in patients with cardiac resynchronization therapy: Implications for clinical trial design and clinical practice
Autor: | Arnaud Denis, Irene E. van Geldorp, Patrizio Pascale, Zachary I. Whinnett, Philippe Ritter, Michel Haïssaguerre, Sylvain Ploux, Darrel P. Francis, Maxime De Guillebon, Keith Willson, Kenneth A. Ellenbogen, Pierre Bordachar |
---|---|
Přispěvatelé: | British Heart Foundation |
Rok vydání: | 2013 |
Předmět: |
Male
Cardiac & Cardiovascular Systems medicine.medical_treatment Hemodynamics Ventricular Function Left Electrocardiography Medicine Cardiac resynchronization therapy medicine.diagnostic_test Atrioventricular delay optimization Dilated cardiomyopathy Av delay Middle Aged Atrioventricular node Reproducibility Treatment Outcome medicine.anatomical_structure Atrioventricular Node cardiovascular system Cardiology HEART-FAILURE Female Cardiology and Cardiovascular Medicine Life Sciences & Biomedicine circulatory and respiratory physiology Adult medicine.medical_specialty Heart Ventricles 1102 Cardiovascular Medicine And Haematology Article Internal medicine Humans Aged Heart Failure Science & Technology business.industry Clinical study design ATRIOVENTRICULAR DELAY Reproducibility of Results Biventricular pacing DILATED CARDIOMYOPATHY medicine.disease Cardiovascular System & Hematology Heart failure Cardiovascular System & Cardiology Hemodynamic optimization business Follow-Up Studies |
Zdroj: | International Journal of Cardiology |
ISSN: | 0167-5273 |
Popis: | Background Reproducibility and hemodynamic efficacy of optimization of AV delay (AVD) of cardiac resynchronization therapy (CRT) using invasive LV dp/dtmax are unknown. Method and results 25 patients underwent AV delay (AVD) optimisation twice, using continuous left ventricular (LV) dp/dtmax, systolic blood pressure (SBP) and pulse pressure (PP). We compared 4 protocols for comparing dp/dtmax between AV delays:Immediate absolute: mean of 10 s recording of dp/dtmax acquired immediately after programming the tested AVD,Delayed absolute: mean of 10 s recording acquired 30 s after programming AVD,Single relative: relative difference between reference AVD and the tested AVD,Multiple relative: averaged difference, from multiple alternations between reference and tested AVD. We assessed for dp/dtmax, LVSBP and LVPP, test–retest reproducibility of the optimum. Optimization using immediate absolute dp/dtmax had poor reproducibility (SDD of replicate optima = 41 ms; R2 = 0.45) as did delayed absolute (SDD 39 ms; R2 = 0.50). Multiple relative had better reproducibility: SDD 23 ms, R2 = 0.76, and (p |
Databáze: | OpenAIRE |
Externí odkaz: |