Application of the Permutation Entropy over the Heart Rate Variability for the Improvement of Electrocardiogram-based Sleep Breathing Pause Detection
Autor: | Eduardo Hernández-Pérez, Juan L. Navarro-Mesa, S. Martin-Gonzalez, José M. Canino-Rodríguez, Antonio G. Ravelo-García, Ubay Casanova-Blancas, Pedro J. Quintana-Morales, Iván Guerra-Moreno |
---|---|
Rok vydání: | 2015 |
Předmět: |
cepstrum
Feature extraction General Physics and Astronomy lcsh:Astrophysics Logistic regression lcsh:QB460-466 Statistics Cepstrum permutation entropy medicine Heart rate variability lcsh:Science Mathematics business.industry logistic regression Sleep apnea Statistical model Pattern recognition Quadratic classifier sleep apnea medicine.disease lcsh:QC1-999 Statistical classification electrocardiogram derived respiratory lcsh:Q Artificial intelligence business lcsh:Physics |
Zdroj: | Entropy Volume 17 Issue 3 Pages 914-927 Entropy, Vol 17, Iss 3, Pp 914-927 (2015) |
ISSN: | 1099-4300 |
DOI: | 10.3390/e17030914 |
Popis: | In this paper the permutation entropy (PE) obtained from heart rate variability (HRV) is analyzed in a statistical model. In this model we also integrate other feature extraction techniques, the cepstrum coefficients derived from the same HRV and a set of band powers obtained from the electrocardiogram derived respiratory (EDR) signal. The aim of the model is detecting obstructive sleep apnea (OSA) events. For this purpose, we apply two statistical classification methods: Logistic Regression (LR) and Quadratic Discriminant Analysis (QDA). For testing the models we use seventy ECG recordings from the Physionet database which are divided into equal-size learning and testing sets. Both sets consist of 35 recordings, each containing a single ECG signal. In our experiments we have found that the features extracted from the EDR signal present a sensitivity of 65.6% and specificity of 87.7% (auc = 85) in the LR classifier, and sensitivity of 59.4% and specificity of 90.3% (auc = 83.9) in the QDA classifier. The HRV-based cepstrum coefficients present a sensitivity of 63.8% and specificity of 89.2% (auc = 86) in the LR classifier, and sensitivity of 67.2% and specificity of 86.8% (auc = 86.9) in the QDA. Subsequent tests show that the contribution of the permutation entropy increases the performance of the classifiers, implying that the complexity of RR interval time series play an important role in the breathing pauses detection. Particularly, when all features are jointly used, the quantification task reaches a sensitivity of 71.9% and specificity of 92.1% (auc = 90.3) for LR. Similarly, for QDA the sensitivity is 75.1% and the specificity is 90.5% (auc = 91.7). |
Databáze: | OpenAIRE |
Externí odkaz: |