Effect of Thigh-Compression Shorts on Muscle Activity and Soft-Tissue Vibration During Cycling
Autor: | Pierre Samozino, William Bertucci, Frédérique Hintzy, Nicolas Gregoire, Xavier Chiementin, Jérémy Rossi |
---|---|
Přispěvatelé: | Institut de Thermique, Mécanique, Matériaux (ITheMM), Université de Reims Champagne-Ardenne (URCA) |
Rok vydání: | 2019 |
Předmět: |
Adult
Male Materials science Vastus lateralis muscle Musculoskeletal Physiological Phenomena 0206 medical engineering Physical Therapy Sports Therapy and Rehabilitation 02 engineering and technology Electromyography Thigh Vibration Quadriceps Muscle Young Adult [SPI]Engineering Sciences [physics] Compression Bandages medicine Humans Orthopedics and Sports Medicine Muscle Skeletal Physical Therapy Modalities ComputingMilieux_MISCELLANEOUS medicine.diagnostic_test General Medicine Compression garment 021001 nanoscience & nanotechnology Compression (physics) 020601 biomedical engineering Bicycling Intensity (physics) medicine.anatomical_structure 0210 nano-technology Cycling Biomedical engineering |
Zdroj: | Journal of Strength and Conditioning Research Journal of Strength and Conditioning Research, Lippincott, Williams & Wilkins, 2019, 33 (8), pp.2145-2152. ⟨10.1519/JSC.0000000000002402⟩ |
ISSN: | 1064-8011 1533-4287 |
Popis: | Hintzy, F, Gregoire, N, Samozino, P, Chiementin, X, Bertucci, W, and Rossi, J. Effect of thigh-compression shorts on muscle activity and soft-tissue vibration during cycling. J Strength Cond Res 33(8): 2145-2152, 2019-This study examined the effects of different levels of thigh compression (0, 2, 6, and 15 mm Hg) in shorts on both vibration and muscle activity of the thigh during cycling with superimposed vibrations. Twelve healthy males performed a 18-minute rectangular cycling test per shorts condition (randomized cross-over design) on a specifically designed vibrating cycloergometer. Each test was composed of 2 intensity levels (moderate then high) and 3 vibration frequencies of 18.3, 22.4, and 26.3 Hz, corresponding to cadences of 70, 85, and 100 rpm, respectively. Muscle vibrations were measured with 2 triaxial accelerometers located before and on the lower-body compression garment, to quantify, respectively, the input and output vibrations, and vastus lateralis muscle activity was measured using surface electromyography. Both vibration and electromyography signals were measured throughout the tests and quantified using root-mean-square analyses. The study showed that the use of a thigh-compression shorts at 6-15 mm Hg significantly reduced both the vibration transmissibility to the thigh and the muscle activity, with higher effect size at higher superimposed vibrations. The thigh-compression shorts garment therefore seems to be 1 way to dampen vibrations transmitted to the cyclists and then to reduce the negative consequences of these vibrations on muscles. |
Databáze: | OpenAIRE |
Externí odkaz: |