Popis: |
Objectives There is considerable variation in ordering practices for the initial laboratory evaluation of monoclonal gammopathies (MGs) despite clear society guidelines to include serum free light chain (sFLC) testing. We assessed the ability of a clinical decision support (CDS) alert to improve guideline compliance and analyzed its clinical impact. Methods We designed and deployed a targeted CDS alert to educate and prompt providers to order an sFLC assay when ordering serum protein electrophoresis (SPEP) testing. Results The alert was highly effective at increasing the co-ordering of SPEP and sFLC testing. Preimplementation, 62.8% of all SPEP evaluations included sFLC testing, while nearly 90% of evaluations included an sFLC assay postimplementation. In patients with no prior sFLC testing, analysis of sFLC orders prompted by the alert led to the determination that 28.9% (800/2,769) of these patients had an abnormal κ/λ ratio. In 452 of these patients, the sFLC assay provided the only laboratory evidence of a monoclonal protein. Moreover, within this population, there were numerous instances of new diagnoses of multiple myeloma and other MGs. Conclusions The CDS alert increased compliance with society guidelines and improved the diagnostic evaluation of patients with suspected MGs. |