Speech processing in radiology
Autor: | M. Hold, Maximilian F. Reiser, P. Kohz, O. Stark, Harald M. Bonel, B. Scharnberg, Andreas Lienemann, W. Hundt |
---|---|
Rok vydání: | 1999 |
Předmět: |
medicine.medical_specialty
Medical Records Systems Computerized education Radiology Interventional Medical Records Computer Communication Networks Learning potential Computer Systems medicine Humans Radiology Nuclear Medicine and imaging medicine.diagnostic_test Dictation business.industry Interventional radiology General Medicine Speech processing humanities Radiology Information Systems Tape Recording Time and Motion Studies Improvement rate Radiology Transcription (software) business Software |
Zdroj: | European Radiology. 9:1451-1456 |
ISSN: | 1432-1084 0938-7994 |
DOI: | 10.1007/s003300050869 |
Popis: | The goal of this study was to evaluate the recognition rate, learning potential and amount of time needed to complete a report with the Philips speech recognition system SP 6000 (Philips, Best, The Netherlands). Four radiologists dictated reports of interventional radiology, MRI examinations of the musculoskeletal system and CT examinations of the thorax and abdomen with the Philips system using the German language. The recognition rate of each report and improvement rate after each learning phase of the Philips system was assessed. The time needed to complete a report using the Philips system was then compared with the time needed to complete a report using the tape-based system via a time analysis. The average recognition rate for the four radiologists using the Philips system was 79.6 %, which improved to 92.5 % after the third adaptation. Initially, the average time demand to dictate and correct one report was approximately 16.8 min, but this time decreased to 8.1 min after the third adaptation. In contrast, only 3. 6 min were needed to dictate and correct one report using the tape-based system. However, with the speech recognition system, dictation, correction and transcription of the report can be completed within 15 min, whereas with the tape-based system, it takes nearly 1 day. With the Philips system, speech recognition can reach as high as 95 % since each adaptation of the system improves the recognition rate by approximately 5 %. While the Philips system is associated with longer dictation times than the tape-based system, turn-around time for a complete report is substantially shorter with the Philips system than the tape-based system. |
Databáze: | OpenAIRE |
Externí odkaz: |