Effect of manual, preloaded, and automated preloaded injectors on corneal incision architecture after IOL implantation
Autor: | Matilde Buzzi, Gabriele Giuranno, Eleonora Favuzza, Michela Cennamo, Maria Cristina Salvatici, Rita Mencucci |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.medical_specialty
genetic structures Descemet membrane medicine.medical_treatment Intraocular lens Cornea 03 medical and health sciences 0302 clinical medicine Lens Implantation Intraocular Ophthalmology medicine Humans In patient Retrospective Studies Lenses Intraocular Phacoemulsification business.industry Eye bank In vivo analysis University hospital eye diseases Sensory Systems Italy 030221 ophthalmology & optometry Surgery sense organs business 030217 neurology & neurosurgery Ex vivo |
Zdroj: | Journal of Cataract and Refractive Surgery. 46:1374-1380 |
ISSN: | 1873-4502 0886-3350 |
Popis: | PURPOSE To analyze the effects on corneal morphology of manual, preloaded, and automated preloaded intraocular lens (IOL) injectors in eye bank human corneas by environmental scanning electron microscopy (ESEM) and in patients after phacoemulsification using anterior segment optical coherence tomography (AS-OCT). SETTINGS Eye Clinic, Careggi University Hospital, Florence, Italy. DESIGN Retrospective and experimental study. METHODS Seventy-eight corneal incisions were examined after IOL implantation: 30 in human corneas mounted on an artificial chamber using ESEM (ex vivo); 48 in patients undergoing phacoemulsification (in vivo). Three different injectors were used for both analyses: manual (Monarch III, n = 26), manual preloaded (UltraSert, n = 26), and automated preloaded system (AutonoMe, n = 26). Thirty IOLs were implanted in the ex vivo study: 5 intermediate and 5 high dioptric powers for AcrySof IQ (Monarch and UltraSert) and for Clareon (AutonoMe) IOLs. In the in vivo analysis, 16 corneal wounds for each injector were evaluated using AS-OCT; in the ex vivo study, incision width was measured and Descemet membrane detachment, posterior wound retraction, and posterior gape were analyzed. RESULTS In the eye bank corneas, the incision width was significantly wider in the high dioptric power IOL manual subgroup (P < .05), with more Descemet tearing compared with AutonoMe. In the in vivo study, the incidence of Descemet membrane detachment, posterior gape, and wound retraction was lower in the automated preloaded group at 1 postoperative day 1. CONCLUSIONS The automated preloaded injector ensured less trauma to the wound and contributed to preserving the endothelial side of the incision even during the implantation of high-power IOLs and in the early postoperative period. |
Databáze: | OpenAIRE |
Externí odkaz: |