Intra- and inter-examiner reliability of direct facial soft tissue measurements using digital calipers

Autor: Jose A. Bosio, Jessica Pruszynski, Thomas Wirtz, Nikolay Mollov
Rok vydání: 2012
Předmět:
Zdroj: Journal of the World Federation of Orthodontists. 1:e157-e161
ISSN: 2212-4438
Popis: Background The objective of this study is to determine if facial soft tissue measurements using digital calipers can be reliably taken by the same examiner and by a large group of examiners. Materials and Methods Ten examiners performed a set of 18 in-clinic measurements on 10 female and 10 male dental students using a digital caliper twice over a 3-week period. The intra-class correlation coefficient and the Shrout-Fleiss method were used for the statistical analysis. Results Anthropometric intra-examiner reliability was high for all measurements (none fell below R = 0.934). However, inter-examiner reliability exhibited a wide range of values, some reliable (nasal width at widest nostrils [ R = 0.922] and subnasale to upper lip [ R = 0.926]), and others unreliable [base of nose ( R = 0.590), mouth height ( R = 0.585), and soft tissue B point to gnathion ( R = 0.623)]. Conclusion Soft tissue measurements of clearly identifiable points measured by the same examiner produced highly consistent, accurate and reliable measurements. Soft tissue points with poor definition resulted in average-to-poor reliabilities measurements.